EM Digital Panel Meter
Digital panel meter with easy-to-read large bright LED display (height of character: 20mm).
Compact (DIN) size: 48×96mm
Multiple inputs: Selectable thermocouple, RTD and voltage inputs.
|
FEATURES |
|
|
-
Easy-to-read large bright LED display (height of character: 20mm)
-
Multiple inputs: Thermocouple, RTD and voltage
-
Compact (DIN ) size: 48×96mm
-
Suitable to connect with SK-8200 infrared thermometer and SK-RHC series transmitters.
-
Conform to RoHS directives
|
SPECIFICATIONS |
|
|
Display |
7 segment LED (height of character: 20mm) |
Resolution |
Refer to the table below |
Power requirements |
100 to 240V AC ±10% (50/60Hz) |
Power consumption |
11VA (100 to 240V AC) |
Mounting |
Push-in panel (One-touch mount) |
Operating ambient |
Temperature:-10°C to 50°C,Humidity: lower than 90%rh(No condensing),Max. elevation: 2000m |
Display accuracy |
±(0.3%FS+1dgit) within measuring range
Thermocouple input: excluding cold junction temperature compensation accuracy.
Thermocouple B: ±5%FS at lower than 400°C
Thermocouple T,U: ±0.5%FS at -100°C to 0°C
±1%FS at lower than -100°C |
Insulation resistance |
Between input/output terminal-power terminal: more than 500VDC 20MΩ
Between input/output terminal-earth terminal: more than 500VDC 20MΩ |
Dimensions/weight |
(W)96 × (H)48 × (D)111mm (inside100mm) approx. 250g |
|
Table on Measuring range and codes |
|
|
Input |
Code |
Range(°C) |
Range(℉) |
Remarks |
Multiple input
(*1) |
Thermocouple |
B |
01 |
0 to 1800 |
0 to 3300 |
*2 |
R |
02 |
0 to 1700 |
0 to 3100 |
|
S |
03 |
0 to 1700 |
0 to 3100 |
|
K |
04 |
-199.9 to 800.0 |
-300 to 1500 |
|
05 |
0 to 1200 |
0 to 2200 |
|
E |
06 |
0 to 700 |
0 to 1300 |
|
J |
07 |
0 to 600 |
0 to 1100 |
|
T |
08 |
-199.9 to 300.0 |
-300 to 600 |
*3 |
N |
09 |
0 to 1300 |
0 to 2300 |
|
U |
10 |
-199.9 to 300.0 |
-300 to 600 |
*3 |
L |
11 |
0 to 600 |
0 to 1100 |
|
WRe5-26 |
12 |
0 to 2300 |
0 to 4200 |
|
R.T.D. |
Pt |
31 |
-199.9 to 600.0 |
-300 to 1100 |
*4 |
32 |
-100.0 to 100.0
|
-150.0 to 200.0 |
|
JPt |
33 |
-199.9 to 500.0 |
-300 to 1000 |
*4 |
34 |
-100.0 to 100.0
|
-150.0 to 200.0 |
|
Voltage |
0 to 10mV |
71 |
0.0 to 100.0 Scaling possible.
Scaling setting range : -1999 to 9999Unit
Span : 10 to 10000Unit |
0 to 5V |
81 |
1 to 5V |
82 |
0 to 10V |
83 |
|
*1 Factory setting: K thermocouple (code 05: 0 to 1200°C)
*2 Accuracy of B thermocouple at lower than 400°C: ±%FS
*3 Accuracy of T, U thermocouple at -100 to 0°C: ±0.5%FS
at lower than -100 : ±1%FS