D Series
The D167Q (120V) and D257Q (230V), can be used with the R50 Blue Bar and HE Nozzles (each will power up to 100 nozzles in series). These power supplies can also be used with shockless static bars with shielded cable.
The D167Q and D257Q are designed with short circuit protection (no fuse required!) which protects the power supplies in the event of a short in the static eliminator or cable. The units are compact in size and built to perform in rugged manufacturing environments.
F Series
The F167 (120V) and F267 (230V) are among Simco-Ion's most popular power supplies. They can power a variety of shockless static eliminators, including the HS Nozzles (up to 100 nozzles in series), and MEB Bars. The units' compact size and budget friendly price make them customer favorites.
UL, CSA and CE approved.
G Series
The G165 (120V) and G265 (230V) will power up to two Cobra Ionizing Air Guns.
CE approved.
N Series
The N167 (120V) and N267 (230V) are Simco-Ion's most versatile power supplies. They can be used with several shockless static bar models (R50 Blue Bar and MEB Bar). A terminal block connector inside the power supply allows for the connection of up to four static eliminators to one power supply. The units accept either shielded or unshielded cable.
The N167 and N267 are designed with short circuit protection (no fuse required!) which protects the power supply in the event of a short in the static eliminator or cable.
UL, cUL, CE and FM approved.
S Series
The S165 (120V) and S265 (230V) are used to power several shockless static eliminators including SM Static Bars and R55 Ionizing Air Nozzles.
The units are compact in size and built to perform in rugged manufacturing environments.
UL and CE approved.
Specifications
Model |
D Series |
F Series |
G Series (G165 | G265) |
N Series (N167 | N267) |
S Series (S165S | S265S) |
Input Requirements
|
D167Q: 120V, 50/60 Hz
D257Q: 230V, 50/60 Hz |
F167:120V, 50/60 Hz
F267: 230V, 50/60 Hz |
120V, 50/60 Hz | 230V, 50/60 Hz |
120V, 60 Hz | 230V, 60Hz |
120V, 60 Hz | 230V, 60Hz |
Output Voltage |
7 kV, 3mA max |
7 kV, 3mA max |
5 kV, 3mA max |
7 kV, 3mA max |
5 kV, 3mA max |
Number of outputs for static eliminators |
2 |
2 |
2 Gun Capacity |
4 |
2 |
Max Length of static bars which can be attached |
200 inches |
200 inches |
N/A |
300 inches |
200 inches |
Shielded cable compatibility |
Yes |
No |
N/A |
Yes |
Short Lengths |
Approval |
UL, CSA, CE |
N/A |
N/A |
N/A |
N/A |
Acceptable for hazardous locations |
N/A |
No |
No |
No |
No |
Part Numbers |
|
|
4002996 | N/A |
4002321 | 4002322 |