Measuring function |
|
|
AC |
|
|
Measuring range |
Resolution |
Accuracy |
|
200 mV |
0.1 mV |
± (0.8% + 5 digits) |
|
2V |
1 mV |
± (0.8% + 5 digits) |
|
20V |
0.01V |
± (0.8% + 5 digits) |
|
200V |
0.1V |
± (0.8% + 5 digits) |
|
750V |
1V |
± (0.8% + 5 digits) |
|
|
|
|
|
Maximum input voltage: 750V AC |
|
Frequency range: 40 ... 400 Hz |
|
Conversion RMS |
|
|
|
|
|
DC |
|
|
Measuring range |
Resolution |
Accuracy |
|
200 mV |
0.1 mV |
± (0.5% + 5 digits) |
|
2V |
1 mV |
± (0.5% + 5 digits) |
|
20V |
0.01V |
± (0.5% + 5 digits) |
|
200V |
0.1V |
± (0.5% + 5 digits) |
|
1000V |
1V |
± (0.8% + 5 digits) |
|
|
|
|
|
Maximum input voltage: 1000V DC |
|
|
|
Alternating current |
|
|
Measuring range |
Resolution |
Accuracy |
|
200 μA |
0.1 μA |
± (1.5% + 5 digits) |
|
2000 μA |
1 μA |
± (1.5% + 5 digits) |
|
20-mA |
0.01-mA |
± (1.5% + 5 digits) |
|
200-mA |
0.1-mA |
± (1.5% + 5 digits) |
|
2 A |
0.001 A |
± (3.0% + 5 digits) |
|
20 A |
0.01A |
± (3.0% + 5 digits) |
|
|
|
|
|
Overload protection at μA, mA: 200-mA / 1000V fuse |
|
Overload protection at A: 10 A / 500V fuse |
|
maximum input current μA: 2000 μA |
|
maximum input current mA: 200-mA |
|
maximum input current A: 10 A. |
|
Frequency range: 40 ... 400 Hz |
|
Conversion RMS |
|
|
|
Measuring function |
|
|
Direct current |
|
|
Measuring range |
Resolution |
Accuracy |
|
200 μA |
0.1 μA |
± (1.2% + 5 digits) |
|
2000 μA |
1 μA |
± (1.2% + 5 digits) |
|
20-mA |
0.01-mA |
± (1.2% + 5 digits) |
|
200-mA |
0.1-mA |
± (1.2% + 5 digits) |
|
2 A |
0.001 A |
± (2.0% + 5 digits) |
|
20 A |
0.01A |
± (2.0% + 5 digits) |
|
|
|
|
|
Overload protection at μA, mA: 200-mA / 1000V fuse |
|
Overload protection at A: 10 A / 500V fuse |
|
maximum input current μA: 2000 μA |
|
maximum input current mA: 200-mA |
|
maximum input current A: 10 A. |
|
|
|
Measuring function |
|
|
Resistance |
|
|
Measuring range |
Resolution |
Accuracy |
|
200 Ω |
0.1 Ω |
± (1.0% + 5 digits) |
|
2 kΩ |
0.001 kΩ |
± (1.0% + 5 digits) |
|
20 kΩ |
0.01 kΩ |
± (1.0% + 5 digits) |
|
200 kΩ |
0.1 kΩ |
± (1.0% + 5 digits) |
|
2 MΩ |
0.001 MΩ |
± (1.0% + 5 digits) |
|
20 MΩ |
0.01 MΩ |
± (1.0% + 5 digits) |
|
|
|
|
|
Diode measurement |
|
|
|
Measuring range |
Resolution |
Accuracy |
|
Indicates the forward voltage |
1 mV |
- |
|
|
|
|
|
Continuity test |
|
|
|
Measuring range |
Resolution |
Accuracy |
|
Beep at <70 Ω |
0.1 Ω |
- |
|
|
|
|
|
Other specifications |
|
|
Range selection |
Automatically and manually |
|
Measurement with receiver |
Detecting cable bridges, detecting cable runs |
|
Measurement with network function |
Detection of open and closed circuits, |
|
|
wrong connection, "split pair", "reverse" connection, |
|
|
Network integration test, screening test |
|
Further measurement function |
"NCV" detection, telephone connection testing |
|
Display |
LCD, 1999 digits |
|
Overload indicator |
"OIL" |
|
Automatic shutdown |
After 15 minutes of inactivity |
|
Fuses |
F10A / 500V, F200mA / 1000A |
|
Battery indicator |
Display when battery is discharged |
|
Power supply |
9V block battery |
|
Operating conditions |
0 ... 40°C / 32 ... 104°F |
|
|
-10 ... 50°C / 14 ... 122°F |
|
Dimensions |
195 x 92 x 55 mm / 7.7 x 3.6 x 2.2 in |
|
Weight |
Approx. 400 g / < 1 lb (with batteries) |