Temperature measurement with thermal imaging camera |
|
|
Sampling rate |
3 times per second |
Field of view (FOV) |
21° x 21°C / 0.5 m / 1 ft 7.6" |
Spatial resolution (IFOV) |
4.53 mrad |
Resolution infrared camera |
80 x 80 Pixel |
Thermal sensitivity / NETD |
<0.1°C (0.18°F) at 30°C (86°F) / 100 mK |
Frame rate |
50 Hz |
Focal length |
7.5 mm |
|
|
Sensor type |
uncooled microbolometer |
Spectral range |
8 ... 14 µm |
Measuring range object temperature |
-20 ... 260°C / -4 ... 500°F |
Measurement accuracy |
± 3°C / 5.4°F or 3% of the measured value, at 10 ... 35°C / 50 ... 95°F ambient temperature and > 0°C / 32°F object temperature |
|
|
General Technical Data |
|
Display |
Colour TFT, 6000 points with status display |
Conversion |
TRMS |
Reference standards |
IEC/EN61010-1, IEC/EN61326-1 |
Isolation |
Double |
Pollution degree |
2 |
Overload category |
CAT IV 600 V, CAT III 1000 V |
Battery type |
1 x 7.4V Li-Ion battery, 2300-mAh |
Power supply charger |
100 / 240V AC, 50/60 Hz, 10V DC, 1 A |
Battery level indicator |
Yes |
Automatic shutdown |
After 15, 30 or 60 minutes of inactivity (deactivatable) |
Fuses |
F10A/1000V, 10 x 38 mm (Input 10 A)
F800mA/1000V, 6 x 32 mm (Input mA, µA) |
Test temperature |
18 ... 28°C / 64 ... 82°F |
Operating conditions |
5 ... 40°C / 41 ... 104°F, <80% r.H. |
Storage conditions |
-20 ... 60°C / -4 ... 140°F, <80% r.H. |
Maximum operating height |
2000 m / 2187 yd |
Dimensions |
175 x 85 x 55 mm / 6.9 x 3.3 x 2.1 in |
Weight |
540 g / 1 lb 3oz |
|
|
Technical Data DC Voltage |
|
|
Measuring range |
Resolution |
Measurement accuracy |
Input resistance |
Overload protection |
600 mV |
0.1 mV |
± (0.2% of measurement value + 5 Dgt) |
>10 MΩ |
1000V DC / ACrms |
6V |
0.001V |
± (0.2% of measurement value + 5 Dgt) |
>10 MΩ |
1000V DC / ACrms |
60V |
0.01V |
± (0.2% of measurement value + 5 Dgt) |
>10 MΩ |
1000V DC / ACrms |
600V |
0.1V |
± (0.2% of measurement value + 5 Dgt) |
>10 MΩ |
1000V DC / ACrms |
1000V |
1V |
± (0.2% of measurement value + 5 Dgt) |
>10 MΩ |
1000V DC / ACrms |
|
|
|
|
|
Technical Data AC Voltage (TRMS) |
|
|
Measuring range |
Resolution |
Measurement accuracy
(50 ... 60 Hz) |
Measurement accuracy
(61 Hz ... 1 kHz) |
Overload protection |
6V |
0.001V |
± (0.8% of measurement value +5 Dgt)±
|
(2.4% of measurement value +5 Dgt) |
1000V DC / ACrms |
60V |
0.01V |
± (0.8% of measurement value +5 Dgt) |
± (2.4% of measurement value +5 Dgt) |
1000V DC / ACrms |
600V |
0.1V |
± (0.8% of measurement value +5 Dgt) |
± (2.4% of measurement value +5 Dgt) |
1000V DC / ACrms |
1000V |
1V |
± (0.8% of measurement value +5 Dgt) |
± (2.4% of measurement value +5 Dgt) |
1000V DC / ACrms |
|
|
|
|
|
Technical Data DC and AC voltage (TRMS) |
|
Measuring range |
Resolution |
Measurement accuracy |
Input resistance |
Overload protection |
6V |
0.001V |
± (2.4% of measurement value +20 Dgt) |
>10 MΩ |
1000V DC / ACrms |
60V |
0.01V |
± (2.4% of measurement value +20 Dgt) |
>10 MΩ |
1000V DC / ACrms |
600V |
0.1V |
± (2.4% of measurement value +20 Dgt) |
>10 MΩ |
1000V DC / ACrms |
1000V |
1V |
± (2.4% of measurement value +20 Dgt) |
>10 MΩ |
1000V DC / ACrms |
|
|
|
|
|
Technical Data Direct Current |
|
|
Measuring range |
Resolution |
Measurement accuracy |
Overload protection |
|
600 µA |
0.1µA |
± (0.9% of measurement value +5 Dgt) |
Protection 800-mA / 1000 V |
|
6000 µA |
1 µA |
± (0.9% of measurement value +5 Dgt) |
Protection 800-mA / 1000V |
|
60-mA |
0.01-mA |
± (0.9% of measurement value +5 Dgt) |
Protection 800-mA / 1000V |
|
600-mA |
0.1-mA |
± (0.9% of measurement value +8 Dgt) |
Protection 800-mA / 1000V |
|
10 A |
0.01 A |
± (1.5% of measurement value +5 Dgt) |
Protection 10 A / 1000V |
|
|
|
|
|
|
Technical Data Alternating Current (TRMS) |
|
|
Measuring range |
Resolution |
Measurement accuracy |
Overload protection |
|
600 µA |
0.1 µA |
± (1.2% of measurement value +5 Dgt) |
Protection 800-mA / 1000V |
|
6000 µA |
1 µA |
± (1.2% of measurement value +5 Dgt) |
Protection 800-mA / 1000V |
|
60-mA |
0.01-mA |
± (1.2% of measurement value +5 Dgt) |
Protection 800-mA / 1000V |
|
600-mA |
0.1-mA |
± (1.2% of measurement value +5 Dgt) |
Protection 800-mA / 1000V |
|
10 A |
0.01 A |
± (1.5% of measurement value +5 Dgt) |
Protection 10 A / 1000V |
|
|
|
|
|
|
Technical Data Coil Current |
|
|
Measuring range |
Resolution |
Measurement accuracy
(50 ... 60 Hz) |
Measurement accuracy (61 Hz ... 1 kHz) |
Overload protection |
30 A |
0.01 A |
± (0.8% of measurement value +5 Dgt) |
± (2.4% of measurement value +5 Dgt) |
1000V DC / ACrms |
300 A |
0.1 A |
± (0.8% of measurement value +5 Dgt) |
± (2.4% of measurement value +5 Dgt) |
1000V DC / ACrms |
3000 A |
1 A |
± (0.8% of measurement value +5 Dgt) |
± (2.4% of measurement value +5 Dgt) |
1000V DC / ACrms |
|
|
|
|
|
Technical Data Diode Test |
|
|
Test current |
<1.5-mA |
|
|
|
Maximum voltage at the open circuit |
3.3V DC |
|
|
|
|
|
|
|
|
Resistance and continuity test |
|
|
Measuring range |
Resolution |
Measurement accuracy |
Acoustic warning sound |
Overload protection |
600 Ω |
0.1Ω |
± (0.5% of measurement value +10 Dgt) |
>50 Ω |
1000V DC / ACrms |
6 Ω |
0.001 kΩ |
± (0.5% of measurement value +5 Dgt) |
>50 Ω |
1000V DC / ACrms |
60 kΩ |
0.01 kΩ |
± (0.5% of measurement value +5 Dgt) |
>50 Ω |
1000V DC / ACrms |
600 kΩ |
0.1 kΩ |
± (0.5% of measurement value +5 Dgt) |
>50 Ω |
1000V DC / ACrms |
6 MΩ |
0.001 MΩ |
± (0.5% of measurement value +5 Dgt) |
>50 Ω |
1000V DC / ACrms |
60 MΩ |
0.01 MΩ |
± (2.5% of measurement value +10 Dgt) |
>50 Ω |
1000V DC / ACrms |
|
|
|
|
|
Technical Data Frequency |
|
|
Measuring range |
Resolution |
Measurement accuracy |
Overload protection |
|
40 Hz ... 10 kHz |
0.01 Hz ... 0.001 kHz |
± (0.5% of measurement value) |
1000V DC / ACrms |
|
60 Hz |
0.01 Hz |
± (0.09% of measurement value +5 Dgt) |
1000V DC / ACrms |
|
600 Hz |
0.1 Hz |
± (0.09% of measurement value +5 Dgt) |
1000V DC / ACrms |
|
6 kHz |
0.001kHz |
± (0.09% of measurement value +5 Dgt) |
1000V DC / ACrms |
|
60 kHz |
0.01kHz |
± (0.09% of measurement value +5 Dgt) |
1000V DC / ACrms |
|
600 kHz |
0.1 kHz |
± (0.09% of measurement value +5 Dgt) |
1000V DC / ACrms |
|
6 MHz |
0.001 MHz |
± (0.09% of measurement value +5 Dgt) |
1000V DC / ACrms |
|
10 MHz |
0.01 MHz |
± (0.09% of measurement value +5 Dgt) |
1000V DC / ACrms |
|
|
|
|
|
|
Technical Data Duty Cycle |
|
|
Measuring range |
Resolution |
Measurement accuracy |
|
|
5 ... 95% |
0.1% |
± (1.2% of measurement value +2 Dgt) |
|
|
|
|
|
|
|
Technical Data Capacitance |
|
|
Measuring range |
Resolution |
Measurement accuracy |
Overload protection |
|
60 nF |
0.01 nF |
± (1.5% of measurement value +20 Dgt) |
1000V DC / ACrms |
|
600 nF |
0.1 nF |
± (1.2% of measurement value +8 Dgt) |
1000V DC / ACrms |
|
6 µF |
0.001 µF |
± (1.5% of measurement value +8 Dgt) |
1000V DC / ACrms |
|
60 µF |
0.01 µF |
± (1.2% of measurement value +8 Dgt) |
1000V DC / ACrms |
|
600 µF |
0.1 µF |
± (1.5% of measurement value +8 Dgt) |
1000V DC / ACrms |
|
6000 µF |
1 µF |
± (2.5% of measurement value +20 Dgt) |
1000V DC / ACrms |
|
|
|
|
|
|
Technical Data Temperature (Thermoelement Type K) |
|
Measuring range |
Resolution |
Measurement accuracy |
Overload protection |
|
-40 ... 600°C / -40 ... 1112°F |
0.1°C / 0.18°F |
± (1.5% of measurement value 3°C / 5.4°F) |
1000V DC / ACrms |
|
600 ... 1000°C / 1112°F ... 1832°F |
1°C / 1.8°F |
± (1.5% of measurement value 3°C / 5.4°F) |
1000V DC / ACrms |