Electrical specifications |
Voltage Measurement (AC V) |
Measurement Range |
Resolution |
Accuracy |
10 V ... 600 V (phase to neutral) |
0.1 V |
±(0.5 % + 0.5 V) |
10 V ... 600 V (phase to phase |
0.1 V |
±(0.5 % + 0.5 V) |
Current Measurement (AC A) Set 1 |
Measurement Range |
Resolution |
Accuracy |
20 A |
0.001 A (< 10 A)
0.01 A (≥ 10 A) |
± (0.5 % + 0.1 A) |
200 A |
0.01 A (< 100 A)
0.1 A (≥ 100 A) |
± (0.5 % + 0.5 A) |
1200 A |
0.1 A (< 1000 A)
1 A (≥ 1000 A) |
± (0.5 A + 5 A) |
Current measurement (AC A) Set 2 |
Measurement range |
Resolution |
Accuracy |
30 A |
0.001 A (< 10 A)
0.01 A (≥ 10 A) |
±(0.5 % + 0.1 A) |
300 A |
0.01 A (< 10 A)
0.1 A (≥ 10 A) |
±(0.5 % + 0.5 A) |
3000 A |
0.1 A (< 1000 A)
1 A (≥ 1000 A) |
±(0.5 A + 5 A) |
Effective power |
Measurement range |
Resolution |
Accuracy |
0 KW ... 9.999 KW |
0.001 KW |
±(1 % + 0.008 KW) |
10 KW ... 99.99 KW |
0.01 KW |
±(1 % + 0.08 KW) |
100 KW ... 999.9 KW |
0.1 KW |
±(1 % + 0.8 KW) |
1 MW ... 9.999 MW |
0.001 MW |
±(1 % + 0.008 MW) |
Apparent Power |
Measurement range |
Resolution |
Accuracy |
0 KVA ... 9.999 KVA |
0.001 KVA |
±(1 % + 0.008 KVA) |
10 KVA ... 99.99 KVA |
0.01 KVA |
±(1 % + 0.08 KVA) |
100 KVA ... 999.9 KVA |
0.1 KVA |
±(1 % + 0.8 KVA) |
1 MVA ... 9.999 MVA |
0.001 MVA |
±(1 % + 0.008 MVA) |
Reactive Power |
Measurement range |
Resolution |
Accuracy |
0 KVAR ... 9.999 KVAR |
0.001 KVAR |
±(1 % + 0.008 KVAR) |
10 KVAR ... 99.99 KVAR |
0.01 KVAR |
±(1 % + 0.08 KVAR) |
100 KVAR ... 999.9 KVAR |
0.1 KVAR |
±(1 % + 0.8 KVAR) |
1 MVAR ... 9.999 MVAR |
0.001 MVAR |
±(1 % + 0.008 MVAR) |
Active Energy |
Measurement range |
Resolution |
Accuracy |
0 KWH ... 9.999 KWH |
0.001 KWh |
±(2 % + 0.008 KWh) |
10.00 KWH ... 99.99 KWH |
0.01 KWh |
±(2 % + 0.08 KWh) |
100.0 KWH ... 999.9 KWH |
0.01 KWh |
±(2 % + 0.8 KWh) |
1 MWH ... 9.999 MWH |
0.001 MMh |
±(2 % + 0.008 MWh) |
Apparent Energy |
Measurement range |
Resolution |
Accuracy |
0 KVARH ... 9.999 KVARH |
0.001 KVARh |
± (2 % + 0.008 KVARh) |
10.00 KVARH ... 99.99 KVARH |
0.01 KVARh |
± (2 % + 0.08 KVARh) |
100.0 KVARH ... 999.9 KVARH |
0.01 KVARh |
± (2 % + 0.8 KVARh) |
1 MVARH ... 9.999 MVARH |
0.001 MVARh |
± (2 % + 0.008 MVARh) |
Power Factor |
Measurement range |
Resolution |
Accuracy |
0 ... 1 |
0.01 |
± 0.04 |
Delay Angle |
Measurement range |
Resolution |
Accuracy |
-180° ... +180° |
0.1° |
±1° |
Frequency |
Measurement range |
Resolution |
Accuracy |
45 Hz ... 65 Hz |
0.1 Hz |
± 0.1 Hz |
Harmonic of AC Voltage at 50 / 60 Hz |
Measurement range |
Resolution |
Accuracy |
1 ... 20th order |
0.001 ... 1 A
0.1 % |
± (2 % + 0.5 A)
± (2 % + 10 Digit) |
21 ... 30th order |
0.001 ... 1 A
0.1 % |
± (2 % + 0.5 A)
± (2 % + 10 Digit) |
21 ... 50th order |
0.001 ... 1 A
0.1 % |
not specified |
General specifications |
Display |
3.7 in / 94.0 mm point-matrix LCD (320 * 240 pixel) with LED background lights |
Safety standards |
IEC1010CAT III 600V |
Input resistance AC V |
10 MOhm |
Operating frequency of current clamp |
40 Hz ... 1 kHz |
Tested operating frequency of current clamp |
45 Hz ... 65 Hz |
Overload protection |
AC V
AC A |
720 V RMS
1300 A with current clamp |
Data Storage |
SD memory card |
Refresh interval |
1 second |
Data logging function |
logging with real-time speed on SD memory card |
Record interval |
2 ... 7200 seconds |
Data output (only for live display on computer) |
per USB or RS232, depending on connection cable |
Operating temperature |
0° C ... +50° C / 32° F ... 122° F |
Surrounding humidity |
< 80 % RH
8 x 1.5 V AA batteries |
Voltage Supply |
9 V adapter |
Current Drain |
Measurement Device: 300 mA DC
current clamp: 34 mA DC |
Maximum Wire Diameter |
50 mm / 1.9 in |
Weight |
Measurement Device: 948 g / 33.4 oz (incl. battery)
Current clamp: 467 g / 16.4 oz (incl. cable) |
Dimensions |
Device: 225 mm x 125 mm x 64 mm / 8.8 in x 4.9 in x 2.5 in
Current clamp: 210 mm x 64 mm x 33 mm / 8.2 in x 2.5 in x 1.2 in
Clamp jaw: 86 mm / 3.3 in (exterior) |