Hotline 24/7: 0986951455
Việt Nam English
Sản phầm nổi bật

Máy đo khí Oxy Air Quality Meter Gasman-O2 "Oxygen"

Mã sản phẩm: Gasman-O2
Tình trạng:

Máy đo khí Oxy Air Quality Meter Gasman-O2 "Oxygen"

Liên hệ
Liên hệ
Technical specifications (12 gases choice)
Typical measurement ranges and alarm adjustments
Parameter/Gas Symbol Range Alarm
Inflammable gas CH4 0 ... 100% LEL 20% LEL
Oxygen O2 0 ... 25% v/v 19% and 23% v/v
Hydrogen sulfide H2S 0 ... 100 ppm 5 ppm
Carbon dioxide CO2 0 ... 5 % v/v 0.5 and 1.5% v/v
Carbon monoxide CO 0 ... 500 ppm 30 ppm
Sulfur dioxide SO2 0 ... 20 ppm 1 ppm
Chlorine * CL2 0 ... 5 ppm 0.5 ppm
Nitrogen dioxide* NO2 0 ... 10 ppm 1 ppm
Phosphine PH3 0 ... 5 ppm 0.5 ppm
Ammonia NH3 0 ... 100 ppm 25 ppm
Hydrogen H2 0 ... 1000 ppm 100 ppm
Ozone O3 0 ... 1 ppm 0.1 ppm
* With chlorine and dioxide of nitrogen the suction pump cannot be used to suction the air in the Air Quality Meterr Gasman II.
Sensors (sensors are exchangeable) Response time (T90) Life
Methane 20 s 5 years
Toxic gases 20 s 3 years
Oxygen 10 s minimum 1 year
Acoustic alarms

- 85 dB (a) to 1 m of distance (adjustable tone)
- Tone of regular control that can be disconnected
- Prolonged tone in case of low battery in the gas meter

Optical alarm

- Very clear and flashing LED
- Type of alarm Indicator
- green LED with low frequency flashing as operating indicator

Vibration alarm - Meter vibrates additionally as a complement to the optical and acoustic alarms
Autozero function - In order to adapt the meter to different environmental conditions of measurement (always activate the clean air function)
Display - LCD with backlight
- 10 mm lines to indicate the gas value
- Symbols for: Max Hold, Batt Low, calibration
ground zero, alarm 1 and 2, 15 min and 8 h, alarms TWA
Measurement values memory Adjustable memory intervals, max. capacity of 900 h prolonged with measurement quota of 1 min (depends on the gas concentration)
Power supply Toxic gases and oxygen - interchangeable lithium battery
- 1 year in normal use conditions
in order to load, the charging station is necessary - 2 cells of nickel-metal hydride (reloadable), 8 ... 10 hours of operative duration
Environmental conditions -20° C ... +55° C / -4° F ... +131° F
0 ... 99 % R.H. non condensed
Housing IP 65/67
Dimensions 90 mm x 48 mm x 24 mm /
3.5 in x 1.9 in x 0.94 in
Weight max. 130 g / 0.29 lbs (battery included)
Norms EN 50014, EN 50020, EN 50018, EN 55022
clase B, EN 50081-2, Ex 95C2348X, Ex 65C2349, Ex 95Y1350, IEC 801-3, EN 50082-2, IEC 61508, EN 61779, EN 50721
Authorisation EEx ia (d) IIC T3 or T4
ATEX II 1G EEx ia IIC T4 (-20 ... +55 °C)
(Toxic gases and oxygen)
ATEX II 2G EEx ia d IIC T4 (inflammable gases)