Hotline 24/7: 0986951455
Việt Nam English
Sản phầm nổi bật

Máy đo nhiệt độ Sato SK-150GT

Mã sản phẩm: SK-150GT
Tình trạng:

Máy đo nhiệt độ Sato SK-150GT

Liên hệ
Liên hệ

WBGT Heat Stress Monitor Model SK-150GT


The SK-150GT is a handy type device that can measure temperature, humidity and globe temperature to approximate the WBGT index (*).
This can be used as a guide for preventing heat related illness and estimating heat stress of working and activity related environments.

PURPOSE OF USE  

The SK-150GT is a handy type instrument that can measure WBGT (*) index, temperature, humidity and globe temperature. This can be used as a guide for preventing a heat illness and estimating heat stress of working and activity related environments.
 *WBGT: Wet Bulb Globe Temperature

By visually observing the sensory temperature, a heat stress can be prevented. The SK-150GT would come in handy at following situations.
-
Gymnastic classes or outdoor activities in schools
-
Indoor and outdoor sports activities
-
In high temperature working environments
-
Construction sites
-
Farms

* WBGT Index :
The process for determining the WBGT (Wet Bulb Globe Temperature) is described in ISO 7243 / JIS Z8504, Hot Environments - Estimation of the Heat Stress on Working Man, based on the WBGT Index. The WBGT index is a sensory temperature which can be calculated from wet bulb temperature, globe temperature (radiation heat) and dry bulb temperature. It is necessary to set the measuring ambient before starting since different calculation is needed depending on its measuring ambient.
(1) Indoor (IN): when measuring indoor or outdoor away from direct sun light.
WBGT Index(°C) = 0.7 x Wet Bulb Temperature(°C) + 0.3 Globe x Temperature(°C)
(2) Outdoor (OUT): when measuring outdoor, under direct sun light.
WBGT Index(°C) = 0.7 x Wet Bulb Temperature(°C) + 0.2 x Globe Temperature(°C) + 0.1 × Dry Bulb Temperature(°C)

Heat Stress :
Heat stress is a condition that temperature regulation function decreases by high temperature ambient. This could cause a heat related illness and even ultimately death. The risk can be reduced by observing the surrounding ambient and by being aware of precautions of heat stock such as overheating and dehydration.

FEATURES  

  • Alarm: The alarm is triggered when the measured WBGT value reaches the set value.
  • HOLD function, MAX/MIN function
  • Measuring ambient of WBGT index can be set.
  • Auto power-off (in 20 min.)
  • Carrying case for damage prevention and storing of the instrument.
 

No. 8310-70 Tripod for SK-150GT Model EX-330QSK
Height:1460mm   Weight: 865g

 

A tripod is recommended for continuous measurement. Select a location free from effects of radiation heat.

SPECIFICATIONS

Model SK-150GT
Measuring range Air Temperature (TA) 0.0 to 50.0°C
Globe Temperature (TG) 0.0 to 80.0°C
WBGT Index 0.0 to 50.0°C
Humidity 10.0 to 95.0%rh
Accuracy Air Temperature (TA) ±0.6°C
Globe Temperature (TG) ±2°C
WBGT Index ±2°C
Humidity ±3% rh (20 to 90%rh at20 to 30°C)
±5% rh (other than above)
Resolution Air Temperature (TA) 0.1°C
Globe Temperature (TG) 0.1°C
WBGT Index 0.1°C
Humidity 0.1% rh
Sampling time approx. 2 seconds
WBGT alarm Setting range 20.0 to 49.9 (no cancelation)
Functions Change-over switch for WBGT Index of indoor and outdoor
Auto power-off in approx. 20 min.
MAX/MIN
HOLD
Operation ambient 0 to 50°C, below 95%rh (no condensing)
Storage ambient -10 to 50°C (no condensing)
Power requirement 9VDC Battery 6F22 (006P) x 1
Battery life approx. 600 hours in continuous use (without use of alarm)
Dimensions Main Unit : (W) 71 x (H) 27.5 x (D) 30 mm (without globe)
Globe : Ø 60 mm
Weight approx. 240 g (with battery)
Standard accessories 9VDC Battery 6F22 (006P) x 1
Carrying case