Recording geometry |
Reflection: 8° / d, (SCI and SCE, including UV / exclusive UV) |
|
Permeability: 0° / d, (SCI and SCE, including UV / exclusive UV) |
Size of integration sphere |
154 mm / 6 in |
Spectrophotometric operation |
Concave grid |
Sensor |
256 Pixel CMOS image sensor |
Wavelength interval |
10 nm |
Wavelength spacing |
10 nm |
Measured reflection range |
0 ... 200% |
|
|
Colorimetric index |
WI (ASTM E313, CIE/ISO, AATCC, Hunter) |
|
YI (ASTM D1925, ASTM 313) |
|
TI (ASTM E313, CIE/ISO) |
|
MI (Metamerism Index) |
|
Stain fastness, colour fastness, colour intensity, opacity |
|
Gardner Index, Pt-Co Index, 555 Index |
|
|
Specular component |
SCI, SCE |
Colour ranges |
CIE Lab, XYZ, Yxy, LCh, CIE LUV, Hunter LAB |
|
Munsell, s-RGB, HunterLab, DIN, βxy |
|
|
Formulas for colour inequality |
ΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc(2:1), ΔE*cmc(1:1) |
|
ΔE*00v, ΔE(Hunter), DIN ΔE99 |
|
|
Light source |
D65, A, C, UV, D50, D55, D75, F1, F2, F3 |
|
F4, F5, F6, F7, F8, F9, F10, F11, F12 |
|
|
Viewing angle |
2° / 10° |
Data display |
Spectrogram values, Samples of colour values |
|
Values / graph of colour differences |
|
Pass / Fail result, Colour balance |
|
|
Device error |
Φ 25.4 mm / SCI, ΔE* ab 0.15 |
Measurement mode |
Single measurement, average value measurement |
Location method |
Finding the measuring points by camera |
Power supply |
Power supply input: 100 ... 240 V 50 ... 60 Hz 1.6 A |
|
Power supply output: 24 V 3 ADC |
|
|
Dimensions |
370 x 300 x 200 mm / 14.5 x 11.8 x 7.8 in (W x L x H) |
Lamp lifespan |
5 years / more than 3 million measurements |
Display |
7" TFT Display, capacitive Touchscreen |
Menu languages |
English, Chinese |
Operating conditions |
0 ... 40°C / 32 ... 104°F |
|
0 ... 85% relative humidity (non-condensing) |
Storage conditions |
-20 ... 50°C / -4 ... 122°F |
|
0 ... 85% relative humidity (non-condensing) |
Standards |
CIE No.15, GB/T 3978, GB 2893, GB/T 18833 |
|
ISO7724/1, ASTM E1164, DIN5033 part 7 |
|
|
Data storage |
5000 standards, 40000 samples |
|
(One standard contains SCI and SCE) |
Data Interface |
USB, Bluetooth |
Weight |
16 kg / 35 lb 4 oz |
|
|
Repeatability |
|
Spectral reflection: Φ 25.4 mm / SCI, standard deviation at 0.05% (400 nm ... 700 nm: within 0.04%) |
|
|
Chromaticity for spectral reflection |
Φ 25.4 mm / SCI, standard deviation ΔE * ab 0.01 |
|
|
Spectral transmittance: Φ 25.4 mm / SCI, standard deviation at 0.05% (400 nm ... 700 nm: within 0.04%) |
|
|
Chromaticity for spectral transmittance: |
Φ 25.4 mm / SCI, standard deviation ΔE* ab 0.03 |
|
|
Chromaticity accuracies refer to the white calibration standards for 30 measurements in a 5 second interval. |
|
|
Measuring aperture |
|
Reflective: |
Φ 30 mm / Φ 25,4 mm, Φ 18 mm / Φ 15 mm
Φ10 mm / Φ 8 mm, Φ 6 mm / Φ 4 mm
|
Permeable: |
Φ 30 mm / Φ 25.4 mm |
|
|
Wavelength range |
360-780 nm combined LED lamp, 400 nm cut-off, UV lamp |