echnical specifications |
Oscilloscope |
Bandwidth |
20 MHz |
Display |
9.7 cm, TFT 3.8" (320 x 240 pixels), 65,535 colours |
Channels |
1 |
Horizontal component |
Temporal base |
5 ns - 100 s/div |
Current time sample speed |
0.25 S/s ... 100 MS/s |
Accuracy |
100 ppm |
Vertical component |
Sensitivity |
5 mV - 5 V/div |
Input coupling |
DC, AC, GND |
Input resistance |
1 MΩ ±2 % in parallel with 15 pF ± 5 pF |
Maximum input voltage |
400 V/DC and AC ss |
DC3% accuracy |
3 % |
A/D transducer |
8 bit |
Raising flank |
<17.5 ns |
Trigger |
Trigger mode |
flank, videoalternate, |
Trigger |
Trigger |
Trigger coupling |
DC, AC, LF-REJ, HF-REJ |
Measuring functions |
Automatic measurements |
19 parameters |
Mathematic waveform |
addition, subtraction, multiplication, division, FFT |
Memory |
Memory function |
2,000.000 points (1 channel) |
Memory of wave form |
4 waveforms |
Port |
USB |
Digital multimeter |
Measurement Range |
Resolution |
Accuracy |
Continuous tension |
400 mV
4 V
40 V
400 V
1000 V |
0.1 mV
1 mV
10 mV
100 mV
1 V |
± (1.0 % + 2 digits)
± (1.0 % + 2 digits)
± (1.0 % + 2 digits)
± (1.0 % + 2 digits)
± (1.0 % + 2 digits) |
Alternating tension |
4 V
40 V
400 V
750 V |
1 mV
10 mV
100 mV
1 V |
± (1.0 % + 3 digits)
± (1.0 % + 3 digits)
± (1.0 % + 3 digits)
± (1.5 % + 3 digits) |
Continuous current |
40 mA
400 mA
20 A |
10 µA
100 µA
10 mA |
± (1.0 % + 1 digit)
± (1.5 % + 1 digit)
± (3.0 % + 3 digit) |
Alternating current |
40 mA
400 mA
20 A |
10 µA
100 µA
10 mA |
± (1.5 % + 3 digits)
± (2.0 % + 1 digits)
± (5.0 % + 3 digits) |
Resistance |
400 Ω
4 kΩ
40 kΩ
400 kΩ
4 MΩ
40 MΩ |
0.1 Ω
1 Ω
10 Ω
100 Ω
1 kΩ
10 kΩ |
± (1.0 % + 1 digits)
± (1.0 % + 1 digits)
± (1.0 % + 1 digits)
± (1.0 % + 1 digits)
± (1.0 % + 1 digits)
± (1.5 % + 3 digits) |
Capacity |
51.2 nF
512.0 nF
5.12 µF
51.2 µF
100 µF |
10 pF
100 pF
1 nF
10 nF
100 nF |
± (3.0 % + 3 digits)
± (3.0 % + 3 digits)
± (3.0 % + 3 digits)
± (3.0 % + 3 digits)
± (3.0 % + 3 digits) |
Diode test |
0 … 1.5 V |
Continuity test |
acoustic signal<50 Ω |
Technical specifications |
Power supply |
ion-lithium accumulator or net component |
Dimensions (width x height x depth) |
180 x 115 x 40 mm |
Weight |
approx. 455 g |
Absorbed power |
< 3 W |
Norms |
EN 61010-1, CAT II 400 V |
The handheld Milliohmmeter is delivered with a case so the equipment and accessories are well kept. This case will make transportation easier. Therefore, this handheld Milliohmmeter is ideal for mobile work. As the handheld Milliohmmeter offers multiple functions, you do not have to use different equipment, this device will be enough. For continuous measurements, the handheld Milliohmmeter can be powered through network component. For mobile work, the handheld Milliohmmeter has a lithium-ion battery. |