Thiết bị dò khí Gas Detector Xgard-5-CH

Mã sản phẩm: Xgard-5-CH
Tình trạng:

Thiết bị dò khí Gas Detector Xgard-5-CH

Liên hệ
Liên hệ
Technical Specifications for the Xgard series sensors
Gas sensor type Xgard-Type 1 Xgard-Type 5 TCgard
EX Zone 0, 1, 2 1, 2 1, 2
Types of gases to detect with corresponding measurement range
(you will find the required order code for the types of gases in the online store)
O2 0 ... 25 vol%
H2 0 ... 2000 ppm
0 ... 4 vol%
= (100% LEL)
CO 0 ... 250 ppm
H2S 0 ... 25 ppm
H2S 0 ... 25 ppm
CL2 0 ... 5 ppm
O3 0 ... 1 ppm
SO2 0 ... 10 ppm
PH3 0 ... 1 ppm
NH3 0 ... 50 ppm
0 ...100 % UEG
inflammable gases
(methane, procloth, butane, pentane, LPG, ethanol, ethylene, etc.)
By default, the sensor is delivered calibrated to methane. Please consult us for other types of calibration.
Methane 0 ... 100 vol%
CO2 0 ... 100 vol%
He 0 ... 100 vol%
Accuracy ± 3 % ± 3 % ± 3 %
Display - - - - - - - - -
Signal output 2 conductors
4 mA ... 20 mA
3 conductors
4 mA ... 20 mA
3 conductors
4 mA ... 20 mA
Alarm/control relays - - - - - - - - -
Norms ATEX or UL ATEX or UL ATEX or UL
Power supply 8 ... 30 V DC / 24 mA 8 ... 30 V DC / 24 mA 8 ... 30 V DC / 24 mA
Temperature range -20° C ... +50° C
-4° F ... +122° F
-40° C ... +55° C
-40° F ... +131° F
+10° C ... +55° C
+50° F ... +131° F
Weight approx. 1 kg / 2.2 lbs approx. 1 kg / 2.2 lbs approx. 1 kg / 2.2 lbs

Technical Specifications of the Xgard IR series gas sensors (with infrared measuring)
Optional components for the Xgard IR Xgard IR (infrared) Gas sensor type
The response time of infrared gas sensors is T90 < 30 s and zero drift is approx. ± 2% per month. For highly accurate measurements and protecting the sensors exterior, there are some optional protectors. Depending on the installation site, the protector against sunlight may be the perfect option. If the sensors are mounted outside (in the open field) or in halls and pavilions that are frequently cleaned with water or disinfected from time to time, we recommend the water deflector protector. When the sensor is mounted in high humidity environments or offshore applications and vessel installations, we recommend the gas sensor with the cap resistant to rain. The cone collector is often used when you need to detect light gases (e.g. methane). This facilitates the entry of the gas into the sensor. If you have any questions, contact us: +44 ( 0 ) 2380 98703 0

Advantages to the conventional gas sensors: The great advantage of infrared gas sensors is their long life ( > 5 years) and almost inexistent long-term drift. This grealty lowers the cost of calibration. In addition, the sensors have a full temperature compensation. The ATEX, IECEx and UL norms allow them to be used worldwide.
EX Zone 1, 2, 21 / 22
Types of gases to detect with the corresponding range of measurement
(you will find the required order code for the types of gases in the online store)
CO2 0 ... 2 %
CO2 0 ... 5 %
(according to sensor)
0 ... 100% LEL
inflammable gases
(Methane, propane, butane, pentane, LPG, ethanol, ethylene)
Accuracy ±2 % (the whole range)
Display ----
Output signal 3 conductors
4-mA ... 20-mA
Alarm / control relays ----
Norms ATEX actual or UL
Protection IP65 / IP66 with cap resistant to inclement weather
Power supply 10V ... 30V DC / 50-mA
Temperature range -20º C ... +50 ºC
-4º F ... +122º F
Dimensions 156 mm x 166 mm x 111 mm
6.1 in x 6.5 in x 4.4 in
Weight 1 kg / 2.2 lbs (aluminium housing)
Technical Specifications of the TXgard series gas sensors
Gas sensor type TXgard IS+ TXgard Plus Flamgard Plus
EX Zone 0, 1, 2 1, 2 1, 2
Types of gases to detect with the corresponding range of measurement
(you will find the required order code for the types of gases in the online store)
O2 0 ... 25 vol%
CO 0 ... 500 ppm
H2S 0 ... 50 ppm
O3 0 ... 1 ppm
NH3 0 ... 100 ppm
Cl2 0 ... 10 ppm
H2 0 ... 2000 ppm
HCN 0 ... 25 ppm
PH3 0 ... 2 ppm
O2 0 ... 25 vol%
H2S 0 ... 50 ppm
CO 0 ... 500 ppm
ETO 0 ... 10 ppm
0 ... 100 % UEG
inflammable gases
Acetylene (C2H2), ammonia (NH3), butane (C4H10), ethanol (C2H5OH), ethane (C2H6), ethylene (C2H4), hexane (C6H14), hydrogen (H2), LPG, methane (CH4), methanol (CH3OH), pentane (C5H12), steam oil, propane (C3H8), propanol (C3H8O)
Accuracy ±3 % ±3 % ±3 %
Display yes yes yes
Output signal 2 conductors
4-mA ... 20-mA
3 conductors
4-mA ... 20-mA
3 conductors
4-mA ... 20-mA
Alarm / control relays - - - yes yes
Norms ATEX or UL ATEX or UL ATEX or UL
Power supply 11 V ... 30 V DC / 20-mA 10 V ... 30 V DC / 210-mA 10V ... 30V DC / 210-mA
Temperature range -20° C ... +50° C
-4° F ... +122° F
-10° C ... +55 °C
+14° F ... +131° F
-10° C ... +55° C
+14° F ... +131° F
Weight 0.7 kg / 1.5 lbs 2.2 kg / 4.9 lbs 2.2 kg / 4.9 lbs

Technical Specifications for the Gasflag
Warning station without display to connect one of the above sensors. This unit is usually mounted on the wall. When it exceeds the threshold value, it emits an alert tone and flashes a red alarm LED. A relay output can, for example, be connected to an omnidirectional illumination. The response time of the alarm is less than 1 sec. Threshold values can be adjusted. The alarm station is almost always used with a gas sensor. When it is not desired then the sensor itself makes the indication, and the alarm sounds.
Sensor connection 1 sensor can be connected, 2 or 3 conductors
Input 4 mA ... 20-mA
Output relay output with maximum 1 A,
i.e. useful for multidirectional illumination
Sensor connection 2 or 3 conductors / 4-mA ... 20-mA
LEDs indication operating availability: green LED
difficulty: amber LED
limit is exceeded: 2 red LEDs
Display - - -
Operating temperature range -20° C ... +70° C
-4° F ... +158° F
Operating humidity range 0 ... 99 % R.H. non-condensed
Power supply 13V ... 28V DC
Colour RAL7035
Housing ABS plastic
Dimensions 210 mm x 145 mm x 46 mm
8.3 in x 5.7 in x 1.8 in
Weight 0.5 kg / 1.1 lbs
Norms EN 50270/EMC
Protection IP 20

Technical Specifications for the Gasmaster (1 - 4 gas sensors)
Digital display and control panel for gas sensors described above. There are two Gasmaster models: GM 1 for a GM sensor, and 4 for up to 4 sensors (shows 4 values at one time). In addition to the standard analogue output, both types are available with an RS 232 data interface. The device also has relay outputs to activate a multidirectional light. The housing of the apparatus is protected against dust and splashing water. The unit is standard equipped with a battery so it will continue operating in case of a power failure.
Model GM 1 GM 4
Sensors inputs 1 input for one of the gas sensors 4 inputs for 4 gas sensors
Outputs - 1 relay output
(250 VAC/8 A)
- 1 analogue output
(4 ... 20 mA)
- 1 RS 485 digital
- 1 RS 232 digital -optional
- 4 relay outputs
(250 VAC/8 A)
- 4 analogue outputs
(4 ... 20 mA)
- 1 RS 485 digital
- 1 RS 232 digital-optional
Memory for 300 events (alarms, system errors, settings adjustments)
Indicators - digital display for gas in ppb, ppm or %
-backlight
-alarm LED, availability of uses and errors
- digital display for 4 gases in ppb, ppm or %
-backlight
-alarm LED, availability of uses and errors
Alarm indicators Sound: 85 dB sharp beep
Visual: alarm LED
Operating temperature range -10° C ... +50° C
+14° F ... +122° F
Operating humidity range 0 ... 95 % H.r. (non-condensed)
Power supply 90V ... 264 VAC / 50 Hz ... 60 Hz
Battery 1.2 Ah
Housing steel exterior / ABS front panel
Dimensions 288 mm x 278 mm x 10 mm
11.3 in x 10.9 in x 0.4 in
Weight 4.5 kg / 9.9 lbs
Norms EN 50270 (EMC), EN 61010-1 low voltage
Protection IP 54