Specifications
Item |
Specification |
Frequency range |
Acceleration |
8 Hz to 8 kHz, -3 dB (10 Hz to 5 kHz, ±1 dB) |
Velocity |
10 Hz to 1kHz, ±1.5 dB |
Displacement |
10 Hz to 300 Hz, ±1.5 dB |
Measurement range |
Acceleration |
10,100 m/s2 |
Velocity |
10, 100 mm/s rms |
Displacement |
100, 1,000 μmp-p |
Alarm output |
Individual level setting (upper 2 steps ) : 10 to 100 %
Individual 1c contact : maximum capacity DC30 V, 1A
Delay time setting : 1 to 10 seconds
Automatic reset |
Level output |
DC4 – 20 mA (maximum load resistance 300Ω) |
Monitor output |
AC3 VP-P full scale
DC2 V full scale |
Power supply |
AC100 V±10 V, 47 to 63Hz |
Power consumption |
5VA or smaller |
Operational temperature /
humidity range |
0 to +50゚C, 35 to 95%RH (non-condensing) |
Mass / Size |
74(W) X 72(D) X 90(H) mm / approx. 250g |
Standard composition
Item |
Notes |
Pickup (VP-A51IW) |
Piesoelectric accelerometer |
Pickup cable |
5 m long cable with a pick up connector and waterproof cap |
Standard accessories |
-
● screw for pickup attachment M6, hexagonal hole
-
● sems screw for main body installation
-
● hex key wrench
-
● instruction mannual
(with test certification)
|
Other lengths available on request. (Maximum length is 200m)
Option
Item |
Notes |
Mechanical filter
(MCF-6) |
Prevention of incorrect operation on displacement /
velocity measurement. Elimination of high frequency component. |