Fiber sensors 1

Mã sản phẩm:
Tình trạng: Còn hàng

Liên hệ
Liên hệ

Standard models/ Advanced models/ Infrared models

 

Type Standard models
NPN output E3NX-FA11 E3NX-FA6 E3NX-FA11-5 *1
PNP output E3NX-FA41 E3NX-FA8 ---
Connecting method Pre-wired Wire-saving Connector Pre-wired
Inputs/ 
outputs
Outputs 1 output
External inputs ---
Light source (wavelength) Red, 4-element LED (625 nm)
Power supply voltage 10 to 30 VDC, including 10% ripple (p-p)
Power consumption *2 At Power supply voltage of 24 VDC 
Standard Models: 
 Normal mode: 840 mW max. (Current consumption at 35 mA max.) 
 Eco function ON: 650 mW max. (Current consumption at 27 mA max.) 
 Eco function LO: 750 mW max. (Current consumption at 31 mA max.) 

Advanced Models or Model for Sensor Communications Unit: 
 Normal mode: 920 mW max. (Current consumption at 38 mA max.) 
 Eco function ON: 680 mW max. (Current consumption at 28 mA max.) 
 Eco function LO: 800 mW max. (Current consumption at 33 mA max.) 

Infrared models: 
 Normal mode: 1080 mW max. (Current consumption at 45 mA max.) 
 Eco function ON: 920 mW max. (Current consumption at 38 mA max.) 
 Eco function LO: 1020 mW max. (Current consumption at 42 mA max.)
Control output Load power supply voltage: 30 VDC max., open-collector output 
(depends on the NPN/PNP output format) 
Load current: Groups of 1 to 3 Amplifier Units: 100 mA max., 
Groups of 4 to 30 Amplifier Units: 20 mA max. 
(Residual voltage: 
At load current of less than 10 mA: 1 V max. 
At load current of 10 to 100 mA: 2 V max.) 
OFF current: 0.1 mA max.
External inputs ---
Indicators 7-segment displays (Sub digital display: green, Main digital display: white) 
Display direction: Switchable between normal and reversed. 
OUT indicator (orange), L/D indicator (orange), ST indicator (blue), 
DPC indicator (green), and OUT selection indicator 
(orange, only on models with 2 outputs)
Protection circuits Power supply reverse polarity protection, output short-circuit protection, and output reverse polarity protection
Response 
time
Super-high-speed mode (SHS) Operate or reset for model with 1 output: 30 μs (Super High Speed mode (SHS2) of E3NX-FA11-5 is 60 μs each), with 2 outputs: 32 μs
High-speed mode (HS) Operate or reset: 250 μs
Standard mode (Stnd) Operate or reset: 1 ms
Giga-power mode (GIGA) Operate or reset: 16 ms
Sensitivity adjustment Smart Tuning (2-point tuning, full auto tuning, position tuning, maximum sensitivity tuning, power tuning, or percentage tuning (-99% to 99%)) or manual adjustment
Maximum connectable Units 30
No. of 
Units for 
mutual 
interference
prevention 
*4
Super-high-speed mode (SHS)
Note: 2 units when the detection mode is set to Super High Speed mode (SHS2), and for other models, the mutual interference prevention function is disabled.
High-speed mode (HS) 10
Standard mode (Stnd) 10
Giga-power mode (GIGA) 10
Functions Automatic power control 
(APC)
Always enabled.
Dynamic power control 
(DPC)
Provided
Timer Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay 
+ OFF-delay timer: 1 to 9,999 ms
Zero reset Negative values can be displayed. (Threshold value is shifted.)
Resetting settings *5 Select from initial reset (factory defaults) or user reset (saved settings).
Eco mode *6 Select from OFF (digital display lit), Eco ON (digital display not lit), and Eco LO (digital display dimmed).
Bank switching Select from banks 1 to 4.
Power tuning Select from ON, OFF or Execution on power-up.
Output 1 Select from normal detection mode, area detection mode or differential detection mode.
Output 2 ---
External input ---
Hysteresis width Select from standard setting or user setting. For a user setting, the hysteresis width can be set from 0 to 9,999.
Ambient illumination (Receiver side) Incandescent lamp: 20,000 lx max., Sunlight: 30,000 lx max.
Ambient temperature range *7 Operating: 
Groups of 1 or 2 Amplifier Units: -25 to 55°C, 
Groups of 3 to 10 Amplifier Units: -25 to 50°C, 
Groups of 11 to 16 Amplifier Units: -25 to 45°C, 
Groups of 17 to 30 Amplifier Units: -25 to 40°C 
Storage: -30 to 70°C (with no icing or condensation)
Ambient humidity range Operating and storage: 35 to 85% (with no condensation) 
within the surrounding air temperature range shown above
Altitude 2,000 m max.
Installation environment Pollution degree 3
Insulation resistance 20 MΩ min. (at 500 VDC)
Dielectric strength 1,000 VAC at 50/60 Hz for 1 min
Vibration resistance (destruction) 10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance (destruction) 500 m/s2 for 3 times each in X, Y, and Z directions
Weight (packed state/Sensor only) Approx. 115 g/ 
approx. 75 g
Approx. 60 g/ 
approx. 20 g
Approx. 115 g/ 
approx. 75 g
Materials Case Polycarbonate (PC)
Cover Polycarbonate (PC)
Cable PVC
Accessories Instruction Manual

 

 

Type Advanced models
NPN output E3NX-FA21 E3NX-FA7 E3NX-FA7TW E3NX-FA24 ---
PNP output E3NX-FA51 E3NX-FA9 E3NX-FA9TW E3NX-FA54 E3NX-FA54TW
Connecting method Pre-wired Wire-saving Connector M8 Connector
Inputs/ 
outputs
Outputs 2 outputs 1 output 2 outputs 1 output 2 outputs
External inputs 1 input 1 input --- 1 input ---
Light source (wavelength) Red, 4-element LED (625 nm)
Power supply voltage 10 to 30 VDC, including 10% ripple (p-p)
Power consumption *2 At Power supply voltage of 24 VDC 
Standard Models: 
 Normal mode: 840 mW max. (Current consumption at 35 mA max.) 
 Eco function ON: 650 mW max. (Current consumption at 27 mA max.) 
 Eco function LO: 750 mW max. (Current consumption at 31 mA max.) 

Advanced Models or Model for Sensor Communications Unit: 
 Normal mode: 920 mW max. (Current consumption at 38 mA max.) 
 Eco function ON: 680 mW max. (Current consumption at 28 mA max.) 
 Eco function LO: 800 mW max. (Current consumption at 33 mA max.) 

Infrared models: 
 Normal mode: 1080 mW max. (Current consumption at 45 mA max.) 
 Eco function ON: 920 mW max. (Current consumption at 38 mA max.) 
 Eco function LO: 1020 mW max. (Current consumption at 42 mA max.)
Control output Load power supply voltage: 30 VDC max., open-collector output 
(depends on the NPN/PNP output format) 
Load current: Groups of 1 to 3 Amplifier Units: 100 mA max., 
Groups of 4 to 30 Amplifier Units: 20 mA max. 
(Residual voltage: 
At load current of less than 10 mA: 1 V max. 
At load current of 10 to 100 mA: 2 V max.) 
OFF current: 0.1 mA max.
External inputs Refer to *3. --- Refer to *3. ---
Indicators 7-segment displays (Sub digital display: green, Main digital display: white) 
Display direction: Switchable between normal and reversed. 
OUT indicator (orange), L/D indicator (orange), ST indicator (blue), 
DPC indicator (green), and OUT selection indicator 
(orange, only on models with 2 outputs)
Protection circuits Power supply reverse polarity protection, output short-circuit protection, 
and output reverse polarity protection
Response 
time
Super-high-speed mode (SHS) Operate or reset for model with 1 output: 30 μs (Super High Speed mode (SHS2) of E3NX-FA11-5 is 60 μs each), with 2 outputs: 32 μs
High-speed mode (HS) Operate or reset: 250 μs
Standard mode (Stnd) Operate or reset: 1 ms
Giga-power mode (GIGA) Operate or reset: 16 ms
Sensitivity adjustment Smart Tuning (2-point tuning, full auto tuning, position tuning, maximum sensitivity tuning, power tuning, or percentage tuning (-99% to 99%)) or manual adjustment
Maximum connectable Units 30
No. of 
Units for 
mutual 
interference
prevention 
*4
Super-high-speed mode (SHS)
Note: 2 units when the detection mode is set to Super High Speed mode (SHS2), and for other models, the mutual interference prevention function is disabled.
High-speed mode (HS) 10
Standard mode (Stnd) 10
Giga-power mode (GIGA) 10
Functions Automatic power control 
(APC)
Always enabled.
Dynamic power control 
(DPC)
Provided
Timer Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay 
+ OFF-delay timer: 1 to 9,999 ms
Zero reset Negative values can be displayed. (Threshold value is shifted.)
Resetting settings *5 Select from initial reset (factory defaults) or user reset (saved settings).
Eco mode *6 Select from OFF (digital display lit), Eco ON (digital display not lit), and Eco LO (digital display dimmed).
Bank switching Select from banks 1 to 4.
Power tuning Select from ON, OFF or Execution on power-up.
Output 1 Select from normal detection mode, area detection mode or differential detection mode.
Output 2 Select from 
normal 
detection 
mode, 
alarm 
output 
mode, error 
output 
mode or 
differential 
detection 
mode.
--- Select from 
normal 
detection 
mode, 
alarm 
output 
mode, error 
output 
mode or 
differential 
detection 
mode.
--- Select from 
normal 
detection 
mode, 
alarm 
output 
mode, error 
output 
mode or 
differential 
detection 
mode.
External input Select from input OFF, 
tuning, power tuning, 
emission OFF, zero 
reset, or bank switching.
--- Select 
from input 
OFF, 
tuning, 
power 
tuning, 
emission 
OFF, zero 
reset, or 
bank 
switching.
---
Hysteresis width Select from standard setting or user setting. For a user setting, the hysteresis width can be set from 0 to 9,999.
Ambient illumination (Receiver side) Incandescent lamp: 20,000 lx max., Sunlight: 30,000 lx max.
Ambient temperature range *7 Operating: 
Groups of 1 or 2 Amplifier Units: -25 to 55°C, 
Groups of 3 to 10 Amplifier Units: -25 to 50°C, 
Groups of 11 to 16 Amplifier Units: -25 to 45°C, 
Groups of 17 to 30 Amplifier Units: -25 to 40°C 
Storage: -30 to 70°C (with no icing or condensation)
Ambient humidity range Operating and storage: 35 to 85% (with no condensation) 
within the surrounding air temperature range shown above
Altitude 2,000 m max.
Installation environment Pollution degree 3
Insulation resistance 20 MΩ min. (at 500 VDC)
Dielectric strength 1,000 VAC at 50/60 Hz for 1 min
Vibration resistance (destruction) 10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance (destruction) 500 m/s2 for 3 times each in X, Y, and Z directions
Weight (packed state/Sensor only) Approx. 115 g/ 
approx. 75 g
Approx. 60g/approx. 20g Approx. 65 g/ 
approx. 25 g
Materials Case Polycarbonate (PC)
Cover Polycarbonate (PC)
Cable PVC
Accessories Instruction Manual

 

 

Type Infrared models
NPN output E3NX-FAH11 E3NX-FAH6
PNP output E3NX-FAH41 E3NX-FAH8
Connecting method Pre-wired Wire-saving 
Connector
Inputs/ 
outputs
Outputs 1 outputs
External inputs ---
Light source (wavelength) Infrared LED (870nm)
Power supply voltage 10 to 30 VDC, including 10% ripple (p-p)
Power consumption *2 At Power supply voltage of 24 VDC 
Standard Models: 
 Normal mode: 840 mW max. (Current consumption at 35 mA max.) 
 Eco function ON: 650 mW max. (Current consumption at 27 mA max.) 
 Eco function LO: 750 mW max. (Current consumption at 31 mA max.) 

Advanced Models or Model for Sensor Communications Unit: 
 Normal mode: 920 mW max. (Current consumption at 38 mA max.) 
 Eco function ON: 680 mW max. (Current consumption at 28 mA max.) 
 Eco function LO: 800 mW max. (Current consumption at 33 mA max.) 

Infrared models: 
 Normal mode: 1080 mW max. (Current consumption at 45 mA max.) 
 Eco function ON: 920 mW max. (Current consumption at 38 mA max.) 
 Eco function LO: 1020 mW max. (Current consumption at 42 mA max.)
Control output Load power supply voltage: 30 VDC max., open-collector output 
(depends on the NPN/PNP output format) 
Load current: Groups of 1 to 3 Amplifier Units: 100 mA max., 
Groups of 4 to 30 Amplifier Units: 20 mA max. 
(Residual voltage: 
At load current of less than 10 mA: 1 V max. 
At load current of 10 to 100 mA: 2 V max.) 
OFF current: 0.1 mA max.
External inputs ---
Indicators 7-segment displays (Sub digital display: green, Main digital display: white) 
Display direction: Switchable between normal and reversed. 
OUT indicator (orange), L/D indicator (orange), ST indicator (blue), 
DPC indicator (green), and OUT selection indicator 
(orange, only on models with 2 outputs)
Protection circuits Power supply reverse polarity protection, output short-circuit protection, and output reverse polarity protection
Response 
time
Super-high-speed mode (SHS) Operate or reset for model with 1 output: 30 μs (Super High Speed mode (SHS2) of E3NX-FA11-5 is 60 μs each), with 2 outputs: 32 μs
High-speed mode (HS) Operate or reset: 250 μs
Standard mode (Stnd) Operate or reset: 1 ms
Giga-power mode (GIGA) Operate or reset: 16 ms
Sensitivity adjustment Smart Tuning (2-point tuning, full auto tuning, position tuning, maximum sensitivity tuning, power tuning, or percentage tuning (-99% to 99%)) or manual adjustment
Maximum connectable Units 30
No. of 
Units for 
mutual 
interference
prevention 
*4
Super-high-speed mode (SHS)
Note: 2 units when the detection mode is set to Super High Speed mode (SHS2), and for other models, the mutual interference prevention function is disabled.
High-speed mode (HS) 10
Standard mode (Stnd) 10
Giga-power mode (GIGA) 10
Functions Automatic power control 
(APC)
Always enabled.
Dynamic power control 
(DPC)
Provided
Timer Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay 
+ OFF-delay timer: 1 to 9,999 ms
Zero reset Negative values can be displayed. (Threshold value is shifted.)
Resetting settings *5 Select from initial reset (factory defaults) or user reset (saved settings).
Eco mode *6 Select from OFF (digital display lit), Eco ON (digital display not lit), and Eco LO (digital display dimmed).
Bank switching Select from banks 1 to 4.
Power tuning Select from ON or OFF.
Output 1 Select from normal detection mode or area detection mode.
Output 2 ---
External input ---
Hysteresis width Select from standard setting or user setting. For a user setting, the hysteresis width can be set from 0 to 9,999.
Ambient illumination (Receiver side) Incandescent lamp: 20,000 lx max., Sunlight: 30,000 lx max.
Ambient temperature range *7 Operating: 
Groups of 1 or 2 Amplifier Units: -25 to 55°C, 
Groups of 3 to 10 Amplifier Units: -25 to 50°C, 
Groups of 11 to 16 Amplifier Units: -25 to 45°C, 
Groups of 17 to 30 Amplifier Units: -25 to 40°C 
Storage: -30 to 70°C (with no icing or condensation)
Ambient humidity range Operating and storage: 35 to 85% (with no condensation) 
within the surrounding air temperature range shown above
Altitude 2,000 m max.
Installation environment Pollution degree 3
Insulation resistance 20 MΩ min. (at 500 VDC)
Dielectric strength 1,000 VAC at 50/60 Hz for 1 min
Vibration resistance (destruction) 10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance (destruction) 500 m/s2 for 3 times each in X, Y, and Z directions
Weight (packed state/Sensor only) Approx. 115 g/approx. 75 g Approx. 60g/approx. 20g
Materials Case Polycarbonate (PC)
Cover Polycarbonate (PC)
Cable PVC
Accessories Instruction Manual

 

 

*1. This type can prevent mutual interference for two units in the SHS2 mode. 
*2. At Power supply voltage of 10 to 30 VDC 
       Standard Models: 
         Normal mode : 990 mW max. (Current consumption: 33 mA max. at 30 VDC, 65 mA max. at 10 VDC) 
         Eco function ON : 780 mW max. (Current consumption: 26 mA max. at 30 VDC, 42 mA max. at 10 VDC) 
         Eco function LO : 840 mW max. (Current consumption: 28 mA max. at 30 VDC, 45 mA max. at 10 VDC) 
       Advanced Models: 
         Normal mode : 1,020 mW max. (Current consumption: 34 mA max. at 30 VDC, 67 mA max. at 10 VDC) 
         Eco function ON : 810 mW max. (Current consumption: 27 mA max. at 30 VDC, 44 mA max. at 10 VDC) 
         Eco function LO : 870 mW max. (Current consumption: 29 mA max. at 30 VDC, 48 mA max. at 10 VDC) 
       Infrared models: 
         Normal mode : 1,260 mW max. (Current consumption: 42 mA max. at 30 VDC, 80 mA max. at 10 VDC) 
         Eco function ON : 1,050 mW max. (Current consumption: 35 mA max. at 30 VDC, 60 mA max. at 10 VDC) 
         Eco function LO : 1,140 mW max. (Current consumption: 38 mA max. at 30 VDC, 70 mA max. at 10 VDC) 
*3. The following details apply to the input.

 

 

  Contact input (relay or switch) Non-contact input (transistor) Input time*3-1
NPN ON: Shorted to 0 V (Sourcing current: 1 mA 
max.). 
OFF: Open or shorted to Vcc.
ON: 1.5 V max. (Sourcing current: 1 mA max.) 
OFF: Vcc - 1.5 V to Vcc (Leakage current: 0.1 
mA max.)
ON: 9 ms min. 
OFF: 20 ms min.
PNP ON: Shorted to Vcc (Sinking current: 3 mA 
max.). 
OFF: Open or shorted to 0 V.
ON: Vcc - 1.5 V to Vcc (Sinking current: 3 mA 
max.) 
OFF: 1.5 V max. (Leakage current: 0.1 mA max.)
*3-1.Input time is 25 ms (ON)/(OFF) only when (in tUnE) or (in PtUn) input is selected.

 

 

*4. The tuning will not change the number of units. The least unit count among the mutual interference prevention units of E3NX and E3NC. Check the mutual interference prevention unit count and response speed of each model. 
*5. The bank is not reset by the user reset function or saved by the user save function. 
*6. Eco LO is supported for Amplifier Units manufactured in July 2014 or later. 
*7. When the number of connected units is 11 or more, the ambient temperature is less than 50°C.

 

Analog output models/ Model for Sensor Communications Unit

 

Type Analog output models Model for Sensor Communications Unit
NPN output E3NX-FA11AN E3NX-FA0 E3NX-FAH0
PNP output E3NX-FA41AN
Connecting method Pre-wired Connector for Sensor Communications Unit
Inputs/ 
outputs
Outputs 2 outputs --- *1 --- *1
External inputs ---
Light source (wavelength) Red, 4-element LED (625 nm) Infrared LED (870nm)
Power supply voltage 10 to 30 VDC, including 10% ripple (p-p) Supplied from the connector through the communication units.
Power consumption *2 At Power supply voltage of 24 VDC 
Normal mode: 960 mW max. 
(Current consumption at 40 mA max.) 
Eco function ON: 770 mW max. 
(Current consumption at 32 mA max.) 
Eco function LO: 870 mW max. 
(Current consumption at 36 mA max.)
At Power supply voltage of 24 VDC 
Normal mode: 920 mW max. 
(Current consumption at 38 mA max.) 
Eco function ON: 680 mW max. 
(Current consumption at 28 mA max.) 
Eco function LO: 800 mW max. 
(Current consumption at 33 mA max.)
At Power supply voltage of 24 VDC 
Normal mode: 1,080 mW max. 
(Current consumption at 45 mA max.) 
Eco function ON: 920 mW max. 
(Current consumption at 38 mA max.) 
Eco function LO: 1,020 mW max. 
(Current consumption at 42 mA max.)
Control output Load power supply voltage: 
30 VDC max., open-collector output 
(depends on the NPN/PNP output format) 
Load current: Groups of 1 to 3 Amplifier 
Units: 100 mA max., Groups of 4 to 30 
Amplifier Units: 
20 mA max. 
(Residual voltage: 
At load current of less than 10 mA: 1 V max. 
At load current of 10 to 100 mA: 2 V max.) 
OFF current: 0.1 mA max.
---
Analog output Voltage output: 1-5 VDC 
(10 kΩ or more connected load), 
temperature characteristics: 0.3% F.S. / °C
---
Indicators 7-segment displays (Sub digital display: green, Main digital display: white) 
Display direction: Switchable between normal and reversed. 
OUT indicator (orange), L/D indicator (orange), ST indicator (blue), DPC indicator (green), and OUT selection indicator (orange, only on models with 2 outputs)
Protection circuits Power supply reverse polarity protection, output short-circuit protection, and output reve rse polarity protection Power supply reverse polarity protection and output short-circuit protection
Control 
output 
Response
time
Super-high-speed mode (SHS) Operate or reset: 80 μs Operate or reset: 32 μs
High-speed mode (HS) Operate or reset: 250μs Operate or reset: 250 μs
Standard mode (Stnd) Operate or reset: 1 ms Operate or reset: 1 ms
Giga-power mode (GIGA) Operate or reset: 16 ms Operate or reset: 16 ms
Sensitivity adjustment Smart Tuning (2-point tuning, full auto tuning, position tuning, maximum sensitivity tuning, power tuning, percentage tuning (-99% to 99%)) or manual adjustment
Maximum connectable Units 30 With E3NW-ECT: 30 units (When connected to an OMRON NJ-series Controller.) 
With E3NW-CRT: 16 units (Note: E3NX-FAH0 can not be connected.) 
With E3NW-CCL: 16 units
No. of 
Units for 
mutual 
inter- 
ference 
preven- 
tion *3
Super-high-speed mode (SHS) 0 (The mutual interference prevention function is disabled if the detection mode is set to super-high-speed mode.)
High-speed mode (HS) 10
Standard mode (Stnd) 10
Giga-power mode (GIGA) 10
Func- 
tions
Automatic power control (APC) Always enabled.
Dynamic power control (DPC) Provided
Timer Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay + OFF-delay timer: 1 to 9,999 ms
Zero reset Negative values can be displayed. (Threshold value is shifted.)
Resetting settings *4 Select from initial reset (factory defaults) or user reset (saved settings).
Eco mode Select from OFF (digital display lit), Eco ON (digital display not lit), and Eco LO (digital display dimmed).
Bank switching Select from banks 1 to 4.
Power tuning Select from ON or OFF.
Output 1 Select from normal detection mode or area detection mode.
Output 2 Select from Analog scaling or Analog offset Select from normal detection mode, alarm output mode, error output mode or differential detection mode (E3NX-FA0 only).
Hysteresis width Select from standard setting or user setting. For a user setting, the hysteresis width can be set from 0 to 9,999.
Ambient illumination (Receiver side) Incandescent lamp: 20,000 lx max., Sunlight: 30,000 lx max.
Ambient temperature range *5 Operating: 
Groups of 1 or 2 Amplifier Units: -25 to 55°C, 
Groups of 3 to 10 Amplifier Units: -25 to 50°C, 
Groups of 11 to 16 Amplifier Units: -25 to 45°C, 
Groups of 17 to 30 Amplifier Units: -25 to 40°C 
Storage: -30 to 70°C 
(with no icing or condensation)
Operating: 
Groups of 1 or 2 Amplifier Units: 0 to 55°C, 
Groups of 3 to 10 Amplifier Units: 0 to 50°C, 
Groups of 11 to 16 Amplifier Units: 0 to 45°C, 
Groups of 17 to 30 Amplifier Units: 0 to 40°C 
Storage: -30 to 70°C 
(with no icing or condensation)
Ambient humidity range Operating and storage: 35 to 85% (with no condensation) within the surrounding air temperature range shown above
Altitude 2,000 m max.
Installation environment Pollution degree 3
Insulation resistance 20 MΩ min. (at 500 VDC)
Dielectric strength 1,000 VAC at 50/60 Hz for 1 min
Vibration resistance (destruction) 10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance (destruction) 500 m/s2 for 3 times each in X, Y, and Z directions 150 m/s2 for 3 times each in X, Y, and Z directions
Weight (packed state/Sensor only) Approx. 115 g/ 
approx. 75 g
Approx. 65 g/ 
approx. 25 g
Approx. 65 g/ 
approx. 25 g
Materials Case Polycarbonate (PC)
Cover Polycarbonate (PC)
Cable PVC
Accessories Instruction Manual

 

*1. Two sensor outputs are allocated in the programmable logic controller PLC I/O table. 
      PLC operation via Communications Unit enables reading detected values and changing settings. 
*2. At Power supply voltage of 10 to 30 VDC 
      Analog output models: 
        Normal mode : 1,080 mW max. (Current consumption: 36 mA max. at 30 VDC, 75 mA max. at 10 VDC) 
        Eco function ON : 840 mW max. (Current consumption: 28 mA max. at 30 VDC, 55 mA max. at 10 VDC) 
        Eco function LO : 960 mW max. (Current consumption: 32 mA max. at 30 VDC, 65 mA max. at 10 VDC) 
*3. The tuning will not change the number of units. 
      The least unit count among the mutual interference prevention units of E3NX and E3NC. 
      Check the mutual interference prevention unit count and response speed of each model. 
*4. The bank is not reset by the user reset function or saved by the user save function. 
*5. When the number of connected units is 11 or more, the ambient temperature is less than 50°C.

Sensing Distances

Standard models/ Advanced models/ Analog output models

Threaded Models

 

Sensing 
method
Sensing