Hotline 24/7: 0986951455
Việt Nam English
Sản phầm nổi bật

Máy dò khí Interscan 4890-5.00m, 4890-19.99m, 4890-50.0m Portable Analyzer (4000 Series) with Digital Display - Peracetic acid

Mã sản phẩm: 4890-5.00m, 4890-19.99m, 4890-50.0m
Tình trạng:

Máy dò khí Interscan 4890-5.00m, 4890-19.99m, 4890-50.0m Portable Analyzer (4000 Series) with Digital Display - Peracetic acid

Liên hệ
Liên hệ
4890-5.00m, Portable Analyzer (4000 Series) with Digital Display - Peracetic acid

The zero and span drift specifications assume that the analyzer is equilibrated, and is at constant temperature, with a properly maintained sensor. Intrinsically safe version available

Accuracy

± 2.0% of reading, ± 1 least significant digit. (Limited to accuracy of calibration standard)

Repeatability

± 0.5% of full scale

Minimum Detectability

1.0% of full scale

Linearity

± 1.0% of full scale

Zero Drift

± 1.0% of full scale (24 hours)

Span Drift

Less than ± 2.0% of full scale (24 hours)

Calibration

Against standard gas mixture, or via INTERSCAN's Electronic Calibration Service.

Lag Time

Less than 1 second

Range

0-5.00 ppm

Resolution

0.01 ppm

Dimensions

7" H x 4" W x 8.875" D   (178 x 102 x 225 mm)

Weight

4.5 lb    (2.0 kg)

Gas

Peracetic acid

Application

Portable

Note

 
Specifications  

  4890-19.99m  


The zero and span drift specifications assume that the analyzer is equilibrated, and is at constant temperature, with a properly maintained sensor. Intrinsically safe version available

Accuracy

± 2.0% of reading, ± 1 least significant digit. (Limited to accuracy of calibration standard)

Repeatability

± 0.5% of full scale

Minimum Detectability

1.0% of full scale

Linearity

± 1.0% of full scale

Zero Drift

± 1.0% of full scale (24 hours)

Span Drift

Less than ± 2.0% of full scale (24 hours)

Calibration

Against standard gas mixture, or via INTERSCAN's Electronic Calibration Service.

Lag Time

Less than 1 second

Range

0-19.99 ppm

Resolution

0.01 ppm

Dimensions

7" H x 4" W x 8.875" D   (178 x 102 x 225 mm)

Weight

4.5 lb    (2.0 kg)

Gas

Peracetic acid

Application

Portable

Note

 
Specifications  


4890-50.0m  


The zero and span drift specifications assume that the analyzer is equilibrated, and is at constant temperature, with a properly maintained sensor. Intrinsically safe version available

Accuracy

± 2.0% of reading, ± 1 least significant digit. (Limited to accuracy of calibration standard)

Repeatability

± 0.5% of full scale

Minimum Detectability

1.0% of full scale

Linearity

± 1.0% of full scale

Zero Drift

± 1.0% of full scale (24 hours)

Span Drift

Less than ± 2.0% of full scale (24 hours)

Calibration

Against standard gas mixture, or via INTERSCAN's Electronic Calibration Service.

Lag Time

Less than 1 second

Range

0-50.0 ppm

Resolution

0.1 ppm

Dimensions

7" H x 4" W x 8.875" D   (178 x 102 x 225 mm)

Weight

4.5 lb    (2.0 kg)

Gas

Peracetic acid

Application

Portable

Note

 
Specifications

Bình luận facebook
Bình luận Form
MÁY ĐO - DÒ KHÍ INTERSCAN
go top