Hotline 24/7: 0986951455
Việt Nam English
Sản phầm nổi bật

Máy dò khí Interscan LD209-1000m, LD209-200m, LD209-50.0m, LD209-5.00m 2-Point Stationary Monitors - LD Series - Hydrogen Peroxide

Mã sản phẩm: LD209-1000m, LD209-200m, LD209-50.0m, LD209-5.00m
Tình trạng:

Máy dò khí Interscan LD209-1000m, LD209-200m, LD209-50.0m, LD209-5.00m 2-Point Stationary Monitors - LD Series - Hydrogen Peroxide

Liên hệ
Liên hệ

LD209-1000m, 2-Point Stationary Monitors - LD Series - Hydrogen Peroxide

 







The zero and span drift specifications assume that the analyzer is equilibrated, and is at constant temperature, with a properly maintained sensor.

Accuracy

± 2.0% of reading, ± 1 least significant digit. (Limited to accuracy of calibration standard)

Repeatability

± 0.5% of full scale

Minimum Detectability

1.0% of full scale

Linearity

± 1.0% of full scale

Zero Drift

± 1.0% of full scale (24 hours)

Span Drift

Less than ± 2.0% of full scale (24 hours)

Calibration

Against standard gas mixture, or via INTERSCAN's Electronic Calibration Service.

Lag Time

Less than 1 second

Range

0-1000 ppm

Resolution

1 ppm

Dimensions

24" H x 20" W x 8.75" D  (610 x 508 x 203 mm), exclusive of alarm signals and enclosure mounting feet

Weight

70 lb   (31.8 kg)

Gas

Hydrogen Peroxide (H2O2)

Number of Detection Points

2

Application

Continuous

Includes Auto Zero

No

Note

 
Specifications  

LD209-200m


The zero and span drift specifications assume that the analyzer is equilibrated, and is at constant temperature, with a properly maintained sensor.

Accuracy

± 2.0% of reading, ± 1 least significant digit. (Limited to accuracy of calibration standard)

Repeatability

± 0.5% of full scale

Minimum Detectability

1.0% of full scale

Linearity

± 1.0% of full scale

Zero Drift

± 1.0% of full scale (24 hours)

Span Drift

Less than ± 2.0% of full scale (24 hours)

Calibration

Against standard gas mixture, or via INTERSCAN's Electronic Calibration Service.

Lag Time

Less than 1 second

Range

0-200 ppm

Resolution

1 ppm

Dimensions

24" H x 20" W x 8.75" D  (610 x 508 x 203 mm), exclusive of alarm signals and enclosure mounting feet

Weight

70 lb   (31.8 kg)

Gas

Hydrogen Peroxide (H2O2)

Number of Detection Points

2

Application

Continuous

Includes Auto Zero

No

Note

 
Specifications  

LD209-50.0m


Specifications  

Accuracy

± 2.0% of reading, ± 1 least significant digit. (Limited to accuracy of calibration standard)

Repeatability

± 0.5% of full scale

Minimum Detectability

1.0% of full scale

Linearity

± 1.0% of full scale

Zero Drift

± 1.0% of full scale (24 hours)

Span Drift

Less than ± 2.0% of full scale (24 hours)

Calibration

Against standard gas mixture, or via INTERSCAN's Electronic Calibration Service.

Lag Time

Less than 1 second

Range

0-50.0 ppm

Resolution

0.1 ppm

Dimensions

24" H x 20" W x 8.75" D  (610 x 508 x 203 mm), exclusive of alarm signals and enclosure mounting feet

Weight

70 lb   (31.8 kg)

Gas

Hydrogen Peroxide (H2O2)

Number of Detection Points

2

Application

Continuous

Includes Auto Zero

No

Note

The zero and span drift specifications assume that the analyzer is equilibrated, and is at constant temperature, with a properly maintained sensor.
 DOWNLOADS
  Gas Detection Applications Primer
  Gas Detection Knowledge Base
  How Do I Get Started?
  Hydrogen Peroxide Monitoring Applications
  Interfering Gas Data
  Sensor Principle of Operation
  Two-Point System Instruction Manual
(PDF, 0KB)
  Interscan Photo Gallery
  Interscan Video Library
  H2O2-Toxic and Hazardous Properties