Hotline 24/7: 0986951455
Việt Nam English
Sản phầm nổi bật

Máy dò khí Interscan LD228-50.0m, LD228-20.0m, LD228-5.00m 2-Point Stationary Monitors - LD Series - Hydrogen Cyanide

Mã sản phẩm: LD228-50.0m, LD228-20.0m, LD228-5.00m
Tình trạng:

Máy dò khí Interscan LD228-50.0m, LD228-20.0m, LD228-5.00m 2-Point Stationary Monitors - LD Series - Hydrogen Cyanide

Liên hệ
Liên hệ

LD228-50.0m

 The zero and span drift specifications assume that the analyzer is equilibrated, and is at constant temperature, with a properly maintained sensor.

Accuracy

± 2.0% of reading, ± 1 least significant digit. (Limited to accuracy of calibration standard)

Repeatability

± 0.5% of full scale

Minimum Detectability

1.0% of full scale

Linearity

± 1.0% of full scale

Zero Drift

± 1.0% of full scale (24 hours)

Span Drift

Less than ± 2.0% of full scale (24 hours)

Calibration

Against standard gas mixture, or via INTERSCAN's Electronic Calibration Service.

Lag Time

Less than 1 second

Range

0-50.0 ppm

Resolution

0.1 ppm

Dimensions

24" H x 20" W x 8.75" D  (610 x 508 x 203 mm), exclusive of alarm signals and enclosure mounting feet

Weight

70 lb   (31.8 kg)

Gas

Hydrogen Cyanide (HCN)

Number of Detection Points

2

Application

Continuous

Includes Auto Zero

No

Note

 
Specifications  

LD228-20.0m

 The zero and span drift specifications assume that the analyzer is equilibrated, and is at constant temperature, with a properly maintained sensor.

Accuracy

± 2.0% of reading, ± 1 least significant digit. (Limited to accuracy of calibration standard)

Repeatability

± 0.5% of full scale

Minimum Detectability

1.0% of full scale

Linearity

± 1.0% of full scale

Zero Drift

± 1.0% of full scale (24 hours)

Span Drift

Less than ± 2.0% of full scale (24 hours)

Calibration

Against standard gas mixture, or via INTERSCAN's Electronic Calibration Service.

Lag Time

Less than 1 second

Range

0-20.0 ppm

Resolution

0.1 ppm

Dimensions

24" H x 20" W x 8.75" D  (610 x 508 x 203 mm), exclusive of alarm signals and enclosure mounting feet

Weight

70 lb   (31.8 kg)

Gas

Hydrogen Cyanide (HCN)

Number of Detection Points

2

Application

Continuous

Includes Auto Zero

Yes

Note

 
Specifications  

LD228-5.00m

 The zero and span drift specifications assume that the analyzer is equilibrated, and is at constant temperature, with a properly maintained sensor.

Accuracy

± 2.0% of reading, ± 1 least significant digit. (Limited to accuracy of calibration standard)

Repeatability

± 0.5% of full scale

Minimum Detectability

1.0% of full scale

Linearity

± 1.0% of full scale

Zero Drift

± 1.0% of full scale (24 hours)

Span Drift

Less than ± 2.0% of full scale (24 hours)

Calibration

Against standard gas mixture, or via INTERSCAN's Electronic Calibration Service.

Lag Time

Less than 1 second

Range

0-5.00 ppm

Resolution

0.01 ppm

Dimensions

24" H x 20" W x 8.75" D  (610 x 508 x 203 mm), exclusive of alarm signals and enclosure mounting feet

Weight

70 lb   (31.8 kg)

Gas

Hydrogen Cyanide (HCN)

Number of Detection Points

2

Application

Continuous

Includes Auto Zero

Yes

Note

 
Specifications  
 