No. of connectable measuring units |
Entire system |
1 to 100 units (Connection disabled aft er connection of 101st unit.) |
Up to 24 connected MG42 hub units |
MG41main unit |
0~4units |
|
MG42hub unit |
0~4units |
|
Connectable measuring units |
|
DK800A/DK800B series, DK10, DK25, DK50, DK100, DK110, DK155, DK205 |
|
Connection cable length |
|
Between MG41 main unit and MG42 hub unit
Total cable length from MG41 main unit: Maximum 30 m(Maximum current: 4 A or less) |
|
Resolution |
|
|
Settable output data resolution and display resolution |
|
Measuring unitsResolution(Input resolution) |
0.1μm |
0.1μm |
0.5μm |
1μm |
5μm |
10μm |
|
0.5μm |
- |
0.5μm |
1μm |
5μm |
10μm |
|
Measuring unit data import capacity |
data transfer10Mbps |
Maximum 10 |
The data for one axis is counted as one data. |
Peak hold function |
|
Calculation of maximum value |
|
|
Peak value is not updated during pause. |
|
|
Output and display data are not updated during latching (internal data is updated) |
|
|
Recalculation of peak value is started by start function. |
|
Output data |
Single axis |
Current value |
|
Addition and subtraction |
Current value |
Single axis calculation of an addition / subtraction axis is not possible(for preventing inconsistencies in calculation). |
Conparetor function |
|
|
Data for each axis (single axis |
|
Comparator setting values |
|
2values |
4values |
8values |
16values |
|
No. of setting value groups |
|
16groups |
8groups |
4groups |
2groups |
|
Ethernet |
|
100Base-T (compliant with IEEE 802.3) 100 Mbps/10 Mbps/1 Mpbs (Auto-negotiation) Command input |
|
Reset function |
|
Current value for each axis is reset (by command). |
|
Preset function |
|
Value is preset to the current value of each axis (by command). |
|
Datum point setting function |
|
Datum point of each axis can be set (by command). |
When master calibration function is not used |
Reference point function |
|
Reference point can be used to relocate the datum point of each axis (by command). |
Master calibration function |
|
Reference point can be used to perform master calibration for each axis (by command). |
|
Measuring unit product information |
|
The product information of the connected measuring unit can be acquired. |
|
Command/setting enabled or disabled for each communication line |
|
|
Ethernet |
CC-Link |
|
Command |
Reset function |
○ |
○ |
|
Preset function |
○ |
○ |
|
Datum point setting function |
○ |
○ |
When master calibration function is not used |
Reference point function |
○ |
○ |
Master calibration function |
○ |
○ |
|
Comparator value setting |
○ |
○ |
|
Comparator group number setting |
○ |
○ |
|
Start |
○ |
○ |
|
Pause |
○ |
○ |
|
Latch |
○ |
○ |
|
Data output |
Current value・Peak value( All axis) |
○ |
× |
|
Current value・Peak value( each unit) |
○ |
○ |
|
Comparator result |
○ |
○ |
|
Alarm( data transfer・Measuring units) |
○ |
○ |
|
Soft ware version |
○ |
○ |
|
Measuring unit product information |
○ |
○ |
|
Comparator result |
Input resolution |
○ |
○ |
|
Display・Resolution |
○ |
○ |
|
Axis addition |
○ |
○ |
|
Comparator mode (2, 4, 8, or 16 values in 1 group) |
○ |
○ |
|
Power supplyPower supply voltage |
Terminal input |
DC12~24V(11~26.4V) |
Use a power supply with a current that is 4 A or higher. (Recommended: +24 V) (for every six MG42 hub units) |
Power consumption |
Note the connection conditions. |
System total: Max. current 4A |
|
When the maximum current is exceeded |
|
|
|
Operating temperature/humidity |
|
0~+50℃(non condensing) |
|
Storage temperature/humidity |
|
-10~+60℃(20~90%RH) |
|
Mass |
|
MG41:300g MG42:250g |
|