Hotline 24/7: 0986951455
Việt Nam English
Sản phầm nổi bật

Bộ chuyển dữ liệu Magnescale Interface MG-40

Mã sản phẩm: MG-40
Tình trạng:

Bộ chuyển dữ liệu Magnescale Interface MG-40

Liên hệ
Liên hệ

Features

 

MG40 series, new measurement system integrates the primary functions of a counter into the gauge itself to a high degree. The MG40 series does not have to count analog outputs or AB phase outputs of the gauge and acquires positional information directly via full digital communication. The theoretical response speed is 20 times faster than the response speed of our previous models. Miscounts, caused by external noise, are eliminated and the system is capable of instantly recovering from a communication error by way of re-reads.

  • Ethernet and CC-Link models are available
  • High-speed and highly reliable communication shortens cycle times
    • High-speed communication via Ethernet
    • Communication error detection
    • High-speed RISC processor dedicated to communication
    • Our proprietary high-speed processor for multi-axis data processing
    • Newly developed ASIC
  • Quick and simple wiring connections
    • Connection via a hub
    • PLC connections
    • Acquiring individual gauge information
    • DIN rail mount and frontal connections
  • Maximized system efficiency
    • On the path to a revolution in quality
    • High-speed measurements enable shorter cycle time
    • Lower overall system costs

Specifications

  
Specifications
Item Conditions Description Remarks

Magnescale reserves the right to change product specifications without prior notice.

No. of connectable measuring units Entire system 1 to 100 units (Connection disabled aft er connection of 101st unit.) Up to 24 connected MG42 hub units
MG41main unit 0~4units  
MG42hub unit 0~4units  
Connectable measuring units   DK800A/DK800B series, DK10, DK25, DK50, DK100, DK110, DK155, DK205  
Connection cable length   Between MG41 main unit and MG42 hub unit
Total cable length from MG41 main unit: Maximum 30 m(Maximum current: 4 A or less)
 
Resolution     Settable output data resolution and display resolution  
Measuring unitsResolution(Input resolution) 0.1μm 0.1μm 0.5μm 1μm 5μm 10μm  
0.5μm - 0.5μm 1μm 5μm 10μm  
Measuring unit data import capacity data transfer10Mbps Maximum 10 The data for one axis is counted as one data.
Peak hold function   Calculation of maximum value  
  Peak value is not updated during pause.  
  Output and display data are not updated during latching (internal data is updated)  
  Recalculation of peak value is started by start function.  
Output data Single axis Current value  
Addition and subtraction Current value Single axis calculation of an addition / subtraction axis is not possible(for preventing inconsistencies in calculation).
Conparetor function     Data for each axis (single axis  
Comparator setting values   2values 4values 8values 16values  
No. of setting value groups   16groups 8groups 4groups 2groups  
Ethernet   100Base-T (compliant with IEEE 802.3) 100 Mbps/10 Mbps/1 Mpbs (Auto-negotiation) Command input  
Reset function   Current value for each axis is reset (by command).  
Preset function   Value is preset to the current value of each axis (by command).  
Datum point setting function   Datum point of each axis can be set (by command). When master calibration function is not used
Reference point function   Reference point can be used to relocate the datum point of each axis (by command).
Master calibration function   Reference point can be used to perform master calibration for each axis (by command).  
Measuring unit product information   The product information of the connected measuring unit can be acquired.  
Command/setting enabled or disabled for each communication line     Ethernet CC-Link  
Command Reset function  
Preset function  
Datum point setting function When master calibration function is not used
Reference point function
Master calibration function  
Comparator value setting  
Comparator group number setting  
Start  
Pause  
Latch  
Data output Current value・Peak value( All axis) ×  
Current value・Peak value( each unit)  
Comparator result  
Alarm( data transfer・Measuring units)  
Soft ware version  
Measuring unit product information  
Comparator result Input resolution  
Display・Resolution  
Axis addition  
Comparator mode (2, 4, 8, or 16 values in 1 group)  
Power supplyPower supply voltage Terminal input DC12~24V(11~26.4V) Use a power supply with a current that is 4 A or higher. (Recommended: +24 V) (for every six MG42 hub units)
Power consumption Note the connection conditions. System total: Max. current 4A  
When the maximum current is exceeded  
 
 
Operating temperature/humidity   0~+50℃(non condensing)  
Storage temperature/humidity   -10~+60℃(20~90%RH)  
Mass   MG41:300g MG42:250g  
 
 
Bình luận facebook
Bình luận Form
go top