I. LS125 UV Light Meter Introduction
LS125 is a smart host that can support 9 different probes. It can intelligently identify different probes. This host is connected to the probe through an aviation plug. The main function of the host is to display the test data. The host equipped with the probe can be used for ultraviolet intensity and energy detection. When using the host, you need to buy the corresponding probe to use with it according to the test needs.
II. LS125 UV Light Meter Parameters
Parameters |
LS125 UV Light Meter |
Weight |
About 194g |
Dimension |
148mm × 76mm × 26mm (L*W*H) |
Display |
240*160 dot matrix LCD |
Power supply |
4 AAA alkaline batteries |
Probe connection |
Push pull (Snap-in style),Aviation socket |
LS125 UV light meter host display
III. LS125 UV Light Meter Application
Ultraviolet light includes UVA band (315nm-420nm), UVB band (280nm-315nm) and UVC band (200nm-280nm). UVA band is mainly used in photocuring, lithographic exposure, ultraviolet light source, integrated circuit lithography and other industries; UVB band UV lamps mainly include physiotherapy lamps in hospitals and health care places, plant growth lamps and UVB fluorescent lamps for reptiles; UVC band also known as short-wave sterilization ultraviolet, ultraviolet germicidal lamps emit UVC short-wave ultraviolet. Ultraviolet germicidal lamps are mainly used for disinfection and sterilization. They are often used in hospitals, transfer windows of drug factories, disease control centers and sewage treatment plants.
The LS125 handheld UV measurement device is widely used. Many of the above industries require different ultraviolet probes to detect the radiation intensity or energy value. We can select the appropriate probe to use with the host refer to the application of the measured light source, the spectral response range and the probe test aperture.
IV. LS125 UV Light Meter Probe Selection
According to the spectral response range, application, measuring range and test aperture size of the light source, we have introduced 9 different types of probes (probe must be purchased separately). The selection table is as follows:
1. Select according to the spectral response range and application of the light source
2. Select according to the range and the test light hole size
No. |
Probe type |
Range |
Test aperture |
1 |
UVC-X0 |
0 - 200000 μW/cm² |
¢10mm |
2 |
UVCWP-X1 |
0 - 200000 μW/cm² |
¢10mm |
3 |
UVCLED-X0 |
0 - 200000 μW/cm² |
¢10mm |
4 |
UVB-X0 |
0 - 200000 μW/cm² |
¢10mm |
5 |
UVA-X0 |
0 - 2000 mW/cm² |
¢10mm |
6 |
UVA-X1 |
0 - 200000 μW/cm² |
¢10mm |
7 |
UVALED-X0 |
0 - 20000 mW/cm² |
¢10mm |
8 |
UVALED-X1 |
0 - 20000 mW/cm² |
¢1mm |
9 |
UVALED-X3 |
0 - 200000 μW/cm² |
¢10mm |
3. Suggestion of Probes for Classic Industry Application
No. |
Application |
Suggested Probe |
1 |
Detect UV aging box |
UVA-X1、UVB-X0 |
2 |
Detect ambient light
and sunlight
|
UVA-X1、UVB-X0
|
3 |
Detect welding arc |
UVA-X1、UVB-X0、
UVC-X0
|
4 |
Detect UV light of
non-destructive testing
|
UVA-X0 |
5 |
Detect UV Nail Lamp |
UVALED-X3 |
6 |
Detect plant growth lamp or
reptile lamp
|
UVB-X0 |
4. Comparison between the old and new models of LS125 host and 9 probes
No. |
New |
Old |
1 |
UVC-X0 |
UVC |
2 |
UVCWP-X1 |
UVC-WP |
3 |
UVCLED-X0 |
UVCLED |
4 |
UVB-X0 |
UVB |
5 |
UVA-X0 |
UVA |
6 |
UVA-X1 |
UVA-X1 |
7 |
UVALED-X0 |
UVALED |
8 |
UVALED-X1 |
UVALED-X3 |
9 |
UVALED-X3 |
UVALED-X3 |
10 |
Host |
Host |
V. LS125 UV Light Meter Characteristics
1. Multi-probe UV light meter. The host and probe are linked by aviation plugs. One host can intelligently match 9 different UV probes to meet different test needs.
Nine probes and LS125 UV detector host (probes are sold separately)
2. Digital probe: adopt advanced digital probe technology, the probe is not easy to be interfered and provides excellent measurement accuracy.
3. The instrument can intelligently identify the probe model and the probe will adapt the display interface automatically.
LS125 UV light meter and UVALED probe
4. A variety of units are available: The instrument can provide different unit selections based on the identified probe model. After connecting the probe, you can choose the appropriate unit in the setting mode.
5. Abundant data statistics function: real-time power value, maximum value, minimum value, average value, measurement time, energy value can be displayed at the same time. (You can also choose not to display the energy value in the setting mode)
LS125 UV detector data detailed explanation
6. Data recording: 9 sets of measurement data can be saved. During the measurement, press the “HOLD” to lock the maximum value and the current value during the measurement at the same time. The data will be saved even after the power is turned off. (Except when the battery is removed)
7. Ultra-low power consumption: The instrument is powered by four AAA batteries. The UV measurement device will automatically shut down after 10 minutes without any operation, which can avoid wasting battery power and prolong the service life of the instrument.