I. LS125 UV Light Meter Introduction

      LS125 is a smart host that can support 9 different probes. It can intelligently identify different probes. This host is connected to the probe through an aviation plug. The main function of the host is to display the test data. The host equipped with the probe can be used for ultraviolet intensity and energy detection. When using the host, you need to buy the corresponding probe to use with it according to the test needs.

II. LS125 UV Light Meter Parameters

Parameters LS125 UV Light Meter
Weight About 194g
Dimension 148mm × 76mm × 26mm (L*W*H)
Display 240*160 dot matrix LCD
Power supply 4 AAA alkaline batteries
Probe connection Push pull (Snap-in style),Aviation socket

 

UV light meter host
LS125 UV light meter host display

III. LS125 UV Light Meter Application

      Ultraviolet light includes UVA band (315nm-420nm), UVB band (280nm-315nm) and UVC band (200nm-280nm). UVA band is mainly used in photocuring, lithographic exposure, ultraviolet light source, integrated circuit lithography and other industries; UVB band UV lamps mainly include physiotherapy lamps in hospitals and health care places, plant growth lamps and UVB fluorescent lamps for reptiles; UVC band also known as short-wave sterilization ultraviolet, ultraviolet germicidal lamps emit UVC short-wave ultraviolet. Ultraviolet germicidal lamps are mainly used for disinfection and sterilization. They are often used in hospitals, transfer windows of drug factories, disease control centers and sewage treatment plants.
      The LS125 handheld UV measurement device is widely used. Many of the above industries require different ultraviolet probes to detect the radiation intensity or energy value. We can select the appropriate probe to use with the host refer to the application of the measured light source, the spectral response range and the probe test aperture.

IV. LS125 UV Light Meter Probe Selection

      According to the spectral response range, application, measuring range and test aperture size of the light source, we have introduced 9 different types of probes (probe must be purchased separately). The selection table is as follows:

1. Select according to the spectral response range and application of the light source

UV light meter probes selection

2. Select according to the range and the test light hole size

No. Probe type Range Test aperture
1 UVC-X0 0 - 200000 μW/cm² ¢10mm
2 UVCWP-X1 0 - 200000 μW/cm² ¢10mm
3 UVCLED-X0 0 - 200000 μW/cm² ¢10mm
4 UVB-X0 0 - 200000 μW/cm² ¢10mm
5 UVA-X0 0 - 2000 mW/cm² ¢10mm
6 UVA-X1 0 - 200000 μW/cm² ¢10mm
7 UVALED-X0 0 - 20000 mW/cm² ¢10mm
8 UVALED-X1 0 - 20000 mW/cm² ¢1mm
9 UVALED-X3 0 - 200000 μW/cm² ¢10mm

3. Suggestion of Probes for Classic Industry Application

No. Application Suggested Probe
1 Detect UV aging box UVA-X1、UVB-X0
2

Detect ambient light 

and sunlight

UVA-X1、UVB-X0

3 Detect welding arc

UVA-X1、UVB-X0、

UVC-X0

4

Detect UV light of 

non-destructive testing

UVA-X0
5 Detect UV Nail Lamp UVALED-X3
6

Detect plant growth lamp or

 reptile lamp

UVB-X0

4. Comparison between the old and new models of LS125 host and 9 probes 

No. New Old
1 UVC-X0 UVC
2 UVCWP-X1 UVC-WP
3 UVCLED-X0 UVCLED
4 UVB-X0 UVB
5 UVA-X0 UVA
6 UVA-X1 UVA-X1
7 UVALED-X0 UVALED
8 UVALED-X1 UVALED-X3
9 UVALED-X3 UVALED-X3
10 Host Host

V. LS125 UV Light Meter Characteristics

1. Multi-probe UV light meter. The host and probe are linked by aviation plugs. One host can intelligently match 9 different UV probes to meet different test needs.

UV light meter probes
Nine probes and LS125 UV detector host (probes are sold separately)

2. Digital probe: adopt advanced digital probe technology, the probe is not easy to be interfered and provides excellent measurement accuracy.

3. The instrument can intelligently identify the probe model and the probe will adapt the display interface automatically.

UV light meter and the probe
LS125 UV light meter and UVALED probe

4. A variety of units are available: The instrument can provide different unit selections based on the identified probe model. After connecting the probe, you can choose the appropriate unit in the setting mode.

5. Abundant data statistics function: real-time power value, maximum value, minimum value, average value, measurement time, energy value can be displayed at the same time. (You can also choose not to display the energy value in the setting mode)

UV light meter measurement interface
LS125 UV detector data detailed explanation

6. Data recording: 9 sets of measurement data can be saved. During the measurement, press the “HOLD” to lock the maximum value and the current value during the measurement at the same time. The data will be saved even after the power is turned off. (Except when the battery is removed)

7. Ultra-low power consumption: The instrument is powered by four AAA batteries. The UV measurement device will automatically shut down after 10 minutes without any operation, which can avoid wasting battery power and prolong the service life of the instrument.