Hotline 24/7: 0986951455
Việt Nam English
Sản phầm nổi bật

For Control Panel - G2RV-SR

Mã sản phẩm: G2RV-SR
Tình trạng: Có hàng

Our Value Design Products Increase the Value of Your Control Panels. Global standard size, low profile slim I/O relay with width 6.2 mm.

Liên hệ
Liên hệ

Ratings

Coil ratings

 

Rated input 
voltage
Rated current Must 
operate 
voltage
Must 
release 
voltage
Power consumption Maximum 
allowable 
voltage
AC DC Percentage of 
the rated voltage
AC (VA) DC (mW) Percentage 
of the rated 
voltage
50 Hz 60 Hz
12 VDC - - 27.9 mA 80% max.* 10% min. - Approx. 300 mW 110%
24 VDC - - 13.5 mA - Approx. 300 mW
24 VAC/VDC 12.5 mA 12.6 mA 12.6 mA Approx. 0.5 VA Approx. 300 mW
48 VAC/VDC 5.9 mA 6.1 mA 5.2 mA Approx. 0.4 VA Approx. 250 mW
100 VAC 5.9 mA 6.0 mA - Approx. 0.8 VA -
110 VAC 5.9 mA 5.9 mA - Approx. 0.8 VA -
200 VAC 6.6 mA 7.6 mA - Approx. 1.7 VA -
230 VAC 7.3 mA 8.4 mA - Approx. 1.7 VA -

 

 

Note: The operating characteristics are measured at ambient temperature of 23°C. 
* Operating voltage will be, for mounting in the upside down direction, 85% max. 
  (Upside down: Direction in which the mechanical indicator faces down)

 

Contact ratings

 

Item Standard 
(G2RV-SR700, 500, 701, 501)
For microloads 
(G2RV-SR700-AP, 
500-AP) *2
Contact configuration SPDT
Load Resistive load 
(cosφ=1)
Inductive load 
(cosφ=0.4, L/R=7ms)
Resistive load 
(cosφ=1)
Rated load 6 A at 250 VAC 
6 A at 30 VDC
2.5 A at 250 VAC 
2 A at 30 VDC
50 mA at 30 VAC 
50 mA at 36 VDC
Rated carry current 6 A 50 mA
Maximum switching voltage 440 VAC, 125 VDC 30 VAC, 36 VDC
Maximum switching current 6 A 50 mA
Maximum switching power 1,500 VA 
180 W
500 VA 
60 W
-
Failure rate P value 
(reference value) *1
10 mA at 5 VDC 1 mA at 100 mVDC

 

*1. P level: λ60=0.1×10-6/times 
     This value is the value in switching frequency 120 operations/min. 
*2. If the Au plating layer is destroyed, the number will be the same as the standard type.

Characteristics

 

Item Standard 
(G2RV-SR700, 500, 701, 501)
For microloads 
(G2RV-SR700-AP, 500-AP)
Contact resistance * 100 mΩ max.
Operate (Set) time * 20 ms max.
Release time * AC, AC/DC: 40 ms max. 
DC: 20 ms max.
Maximum operating 
frequency
Mechanical: 18,000 operations/h 
Electrical: 1,800 operations/h (rated load)
Insulation resistance 1,000 MΩ min. (at 500 VDC)
Dielectric strength Between coil and contacts: 4,000VAC 50/60 Hz 1 min 
Contact between the same polarity: 1,000 VAC 50/60 Hz 1 min
Vibration resistance Destruction: 10 to 55 to 10 Hz, single amplitude 0.50 mm (double amplitude 1.0 mm) 
Malfunction: 10 to 55 to 10 Hz, single amplitude 0.50 mm (double amplitude 1.0 mm)
Shock resistance Destruction: 1,000 m/s2 
Malfunction: Energized 200m/s2, Non-energized 100m/s2
Endurance * Mechanical 5,000,000 operations min.
Electrical NO contact: 70,000 operations min. 
NC contact: 50,000 operations min.
5,000,000 operations min.
Ambient operating 
temperature
Operating: -40 to +55°C (with no icing or condensation)
Ambient operating 
humidity
Operating: 5 to 85% RH
Weight Approx. 30 g
Contact material Ag alloy Ag alloy + Au plating

 

Note: Above values are initial values. 
* Value is at ambient temperature of 23°C.

Approved standards

UL508 (file No.E41643)

 

Model Contact form Operation coil ratings Contact ratings Operations
G2RV-SR series SPDT 12 to 48 VDC 
24 to 230 VAC
6 A at 250 VAC (Resistive load) 
6 A at 30 VDC (Resistive load) 
2 A at 400 VAC (Resistive load)*
6,000

 

* If the load voltage exceeds 250 VAC, please attach with a spacing of 12 mm min., or use a separate plate (XW5Z-EP12).

G2RV-SR Specifications 10

TÜV (EN 61810-1)

 

Model Contact form Operation coil ratings Contact ratings Operations
G2RV-SR series SPDT 12, 24 VDC 
24, 48 VAC/VDC 
100, 110, 200, 230 VAC
6 A at 250 VAC (Resistive load) 
6 A at 30 VDC (Resistive load) 
2 A at 400 VAC (Resistive load)*
50,000 
50,000 
6,000

 

* If the load voltage exceeds 250 VAC, please attach with a spacing of 12 mm min., or use a separate plate (XW5Z-EP12).

G2RV-SR Specifications 12

Lloyd's (File No.07/10020)

 

Model Contact form Operation coil ratings Contact ratings
G2RV-SR500 
G2RV-SR700
SPDT 12, 24 VDC 
24, 48 VAC/VDC 
100, 110, 200, 230 VAC
6 A at 250 VAC (Resistive load)
2.5 A at 250 VAC (PF0.4)
6 A at 30 VAC (Ress)
2 A at 30 VDC (L/R=7ms)
G2RV-SR501 
G2RV-SR701
SPDT 12, 24 VDC 
24 VAC/VDC
6 A at 250 VAC (Resistive load)
2.5 A at 250 VAC (PF0.4)
6 A at 30 VAC (Ress)
2 A at 30 VDC (L/R=7ms)
G2RV-SR500-AP 
G2RV-SR700-AP
SPDT 12, 24 VDC 
24, 48 VAC/VDC 
100, 110, 200, 230 VAC
0.05 A at 30 VAC (Resistive load) 
0.05 A at 36 VDC (Resistive load)