Hotline 24/7: 0986951455
Việt Nam English
Sản phầm nổi bật

Máy kt lực xiết Digital Torque checker Attonic DTC-1, DTC-2, DTC-5, DTC-10, DTC-20, DTC-50, DTC-100, DTC-200

Mã sản phẩm: DTC-1, DTC-2, DTC-5, DTC-10, DTC-20, DTC-50, DTC-100, DTC-200
Tình trạng:

Máy kt lực xiết Digital Torque checker Attonic DTC-1, DTC-2, DTC-5, DTC-10, DTC-20, DTC-50, DTC-100, DTC-200

Liên hệ
Liên hệ
It is more simple and lower-cost torque checker with existing function of ADT-C series, specializing in torque check of electric driver.
 
DTC series - Feature
It is a torque inspecting instrument that specializes in the check of electric drivers.
Of course, it can be used to check manual torque wrenches.
Common bit can be used for checking with standard equipped attachment.
To correspond to customer's special bit, we will do a special processing.
 (Additional cost will be charged.   Please inquire. )
You can choose appropriate measuring range from 8 models from 1Ncm(0.1kgfcm) to 20Nm(200kgfcm)
according to required torque.
The measuring torque value conforms to the torque data of Torque Analyzer (torque analysis system).
External in/output is not provided.
- Accessory
AC adaptor (IN:AC100V-240V OUT:DC9V 500mA) 1 piece
Attachment for electric driver 1 piece
Screw (Excluding a special attachment) for the attachment 2 pieces for each.
Attachment list according to the model
Catalog of DTC series / Manual of DTC series
- Standard issue
Unit of measurement N・m(N・cm)/kgf・cm/in・lb
Accuracy ±0.5%F.S.
Measurement method Peak holding (maximum value)/tracking(present value)
Peak holding Digital analog holding
Response speed MAX.1mS
Display Four digit LCD
Permissive load 120%
Power supply Chargeable battery   Ni-MH(For four charging time hours. )
Basic machine weight About 3.2kg
Model Range of measurement display Range of minimum display Attachment
DTC-1 1.00~10.00N・cm/0.100~1.000kgf・cm/0.100~1.000in・lb 0.01N・cm/0.001kgf・cm/0.001in・lb TC-2、TSS-5
DTC-2 2.0~20.0N・cm/0.20~2.00kgf・cm/0.20~2.00in・lb 0.1N・cm/0.01kgf・cm/0.01in・lb TC-2、TSS-5
DTC-5 5.0~50.0N・cm/0.50~5.00kgf・cm/0.50~5.00in・lb 0.1N・cm/0.01kgf・cm/0.01in・lb TC-2、TSS-5
DTC-10 0.100~1.000N・m/1.00~10.00kgf・cm/1.00~10.00in・lb 0.001N・m/0.01kgf・cm/0.01in・lb TC-3、TSS-10
DTC-20 0.20~2.00N・m/2.0~20.0kgf・cm/2.0~20.0in・lb 0.01N・m/0.1kgf・cm/0.1in・lb TC-3、TSS-20
DTC-50 0.50~5.00N・m/5.0~50.0kgf・cm/5.0~50.0in・lb 0.01N・m/0.1kgf・cm/0.1in・lb TC-6、TSS-30
DTC-100 1.00~10.00N・m/10.0~100.0kgf・cm/10.0~100.0in・lb 0.01N・m/0.1kgf・cm/0.1in・lb TC-4、TSS-30
DTC-200 2.0~20.0N・m/20~200kgf・cm/20~200in・lb 0.1N・m/1kgf・cm/1in・lb TC-4、TSS-30
 
- Function explanation

  Setting of each function can be operated by pushing “FUN”button for seconds.
  Returning to measuring mode is also operated by pushing “FUN”button for seconds.

1. Setting of peak holding mode/tracking mode
  Peak holding: The maximum value of measurement is displayed.
  Tracking: The value of present measurement is displayed.
2. History of memory data
  It is automatically memorized in the internal storage memory by pushing RESET button at peak mode .
   (The value when RESET button is pushed is memorized. )
3. Comparator setting
  The display of HI/LO appears to the display by setting the upper bound value and the lower bound value.
   (When the comparator output of the option is adhered, three kinds of judgments of HI/GO/LO are displayed by this set value. )
4. Setting at each measurement
  3 kinds of unit {Nm(Ncm)/kgfcm/inlb} can be set.
5. Setting of overload
  ”Overload”indication can be displayed by setting maximum limit value of the result.
 (Maximum limit value of the result can be basically set at percentage of the limit value.   It cannot accept over 110% of the limit value. )
  Example ・・・ When you measure the torque of fastening a work with appropriarte attachment, you can use this function to hold the measurement just before breaking the work by setting perticular limit value.
6. Auto power OFF setting
  It is a function that the unit is turned off automatically when it doesn’t work  for over five minutes.
  If the function isn’t set, the unit isn’t turned off until battery shortage display is indicated.
7. Reversing setting of display
  It is a function that the display can be displayed reversely.
8. Battery shortage display
  The battery line decreases when the battery decreases.
  "BATT" appears in display when the battery line disappears.

Bình luận facebook
Bình luận Form
go top